WASHINGTON, PA —
OSHA Inspection: ROSS MOULD, LLC
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of ROSS MOULD, LLC in 259 SOUTH COLLEGE STREET, WASHINGTON, PA 15301 (NAICS 333511). OSHA activity number 339484941.
Where did this inspection happen?
- Establishment
- ROSS MOULD, LLC
- Site address
- 259 SOUTH COLLEGE STREET
- City
- WASHINGTON
- State
- PA
- ZIP
- 15301
- Mailing
- 259 SOUTH COLLEGE STREET, WASHINGTON, PA 15301
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333511
- Employees
- 145
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.95 C01
- Issued
- Abate by
- Penalty
- Initial $3000.00 · Current $1800.00 Reduced
8111
General-duty citation text
29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.95(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent: a) In the Facility, on or about November 26, 2013 - The employer did not institute a continuing effective hearing conservation program when employee noise exposures exceeded an 8-hour time-weighted average sound level of 85 dBA. An employee designated as a Mold Maker was exposed to noise at a level of 66.9% of the allowable limit during a 294 minute sampling period on November 26, 2013. This exposure is equivalent to a sound level of 87.1 dBA for the dose and time of employee exposure and is 1.3 times in excess of the 85 dBA action level (50%) at which the hearing conservation program is required. b) In the Facility, on or about November 26, 2013 - An employee designated as a Cleaner/Mold Maker was exposed to noise at a level of 67.1% of the allowable limit during a 288 minute sampling period on November 26, 2013. This exposure is equivalent to a sound level of 87.1 dBA for the dose and time of employee exposure and is 1.33 times in excess of the 85 dBA action level (50%) at which the hearing conservation program is required.
Recent events (2)
- — I (S) $1800
- — Z (S) $3000
1910.95 G07 II
- Issued
- Penalty
- Initial $0.00 · Current $0.00
8111
General-duty citation text
29 CFR 1910.95(g)(7)(ii): When the annual audiogram shows that an employee has suffered a standard threshold shift, the employer did not obtain a retest within 30 days and consider the results of the retest as the annual audiogram: a) In the Facility, on or about November 26, 2013 - The employer did not obtain a retest within 30 days after an employee suffered a standard threshold shift. An employee designated as a Mold Maker experienced a threshold shift on 10/24/12 and was not provided a retest until 12/18/12.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.95 G08 II B
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
8111
General-duty citation text
29 CFR 1910.95(g)(8)(ii)(B): Unless a physician determines that the standard threshold shift is not work-related or aggravated by occupational noise exposure, the employer did not ensure, when a standard threshold shift occurs, that for employees already using hearing protectors, employees be refitted and retrained in the use of hearing protectors and provided with hearing protectors offering greater attenuation if necessary: a) In the Facility, on or about November 26, 2013 - Employees who have had a standard threshold shift were not refitted and retrained in the use of hearing protection.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at ROSS MOULD, LLC
WASHINGTON, PA—2023-08-31 00:00:00
ROSS MOULD, LLC
WASHINGTON, PA—2013-11-06 00:00:00
ROSS MOULD, LLC
View ROSS MOULD, LLC's full OSHA safety record →
More inspections in this industry (NAICS 333511)
SPRING HOPE, NC—2026-05-26
161247 - ADVANCED PLASTIFORM, INC.
ATHENS, OH—2026-05-21
ATHENS MOLD AND MACHINE
NORTH ROYALTON, OH—2026-05-19
MDF TOOL CORPORATION
MILLERSBURG, OH—2026-05-13
CENTOR A GERRESHEIMER COMPANY
ANOKA, MN—2026-05-12
111218 - THE DYNAMIC GROUP INC
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.
SUNBURY, PA—2026-07-10
DEMPSEY UNIFORM & LINEN SUPPLY, INC
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
WILLIAMSPORT, PA—2026-07-10
INTERNATIONAL PAINT PROS
Source