Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: WON T PAC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of WON T PAC in 100 GREENWOOD AVE, WYNCOTE, PA 19095 (NAICS 238170). OSHA activity number 339494692.

Watch WON T PAC — free Get an email when a new federal OSHA severe-injury report for WON T PAC is published. One employer, no account, unsubscribe in one click.
Establishment
WON T PAC
Site address
100 GREENWOOD AVE
City
WYNCOTE
State
PA
ZIP
19095
Mailing
458 VOLPE ROAD, PLYMOUTH MEETING, PA 19462
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
4
Ownership type
A

4 citations on file for this inspection.

1926.451 B01 II

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $1700.00 · Current $1700.00
29 CFR 1926.451(b)(1)(ii): The platform was not planked or decked as fully as possible and the remaining open space between the platform and the uprights exceeded 9.5 inches (24.1 cm):  a) West side of building-On or about November 5, 2013 employees were observed working from a scaffold that was not fully planked at a height of 10.5' above grade.
Recent events (1)
  • — Z (S) $1700

1926.451 C02

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $1700.00 · Current $1700.00
29 CFR 1926.451(c)(2):   Supported scaffold poles, legs, posts, frames,  or uprights did not bear on base plates, mud sills or other adequate firm foundation:  a) West side of building - On or about November 5, 2013 employees were conducting stucco work and were using a tubular welded frame scaffold to work on the wall and eaves that was not supported by base plates or other firm foundation.
Recent events (1)
  • — Z (S) $1700

1926.451 F03

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $1700.00 · Current $1700.00
29 CFR 1926.451(f)(3):   Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift.  a) West side of building - On or about November 5, 2013, employees are working on a scaffold, with highly visible defects including fall hazards, lack of base plates or mud sills that was not inspected by a competent person prior to use.
Recent events (1)
  • — Z (S) $1700

1926.451 G01

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $1700.00 · Current $1700.00
29 CFR 1926.451(g)(1):   Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section:  a) East side of building - On or about November 5, 2013, employees were working on multiple sections of tubular welded frame scaffolding that were not fully planked, creating fall hazards from no less than 10.5 feet above grade due to the complete lack of installed guard rails or other fall protection equipment.