Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SOUTHERN VAC, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SOUTHERN VAC, LLC in 2750 E. MAIN STREET, GRAND PRAIRIE, TX 75050 (NAICS 332999). OSHA activity number 339502874.

Watch Southern VAC, LLC — free Get an email when a new federal OSHA severe-injury report for Southern VAC, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
SOUTHERN VAC, LLC
Site address
2750 E. MAIN STREET
City
GRAND PRAIRIE
State
TX
ZIP
75050
Mailing
2750 E. MAIN STREET, GRAND PRAIRIE, TX 75050
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
45
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $4900.00 · Current $2200.00 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in the activities covered by this section:    This violation was discovered on or about November 27, 2013, where employees, who maintained and serviced equipment and machinery such as but not limited to shears, benders and band saws throughout the facility that had multiple sources of energy, did not utilize energy control procedures to prevent the unexpected energizing, startup or release of stored energy which could cause injury.
Recent events (2)
  • — I (S) $2200
  • — Z (S) $4900

1910.179 L03 II A

Other-than-serious 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $4900.00 · Current $1000.00 Reduced
29 CFR 1910.179(l)(3)(ii)(a): Adjustments were not maintained to assure correct functioning of all operating mechanisms.    This violation was discovered on or about November 27, 2013, where employees, who operated a Krando overhead crane were exposed to struck-by hazards due to the missing (inoperative) emergency stop botton on the pendent control.
Recent events (2)
  • — I (O) $1000
  • — Z (S) $4900

1910.305 B01 II

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $4900.00 · Current $1000.00 Reduced
29 CFR 1910.305(b)(1)(ii): The employer did not ensure that unused openings in boxes, cabinets, or fittings were effectively closed.    This violation was discovered on or about November 27, 2013, where employees, who are required to open an electrical cabinet with missing breakers are exposed to electrical hazards.  Employee required to turn electrical power (breakers) on for building.
Recent events (2)
  • — I (O) $1000
  • — Z (S) $4900

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339502874.