NORCROSS, GA —
OSHA Inspection: NUBIOLA, LLC
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of NUBIOLA, LLC in 6369 PEACHTREE STREET, NORCROSS, GA 30071 (NAICS 325131). OSHA activity number 339503120.
Where did this inspection happen?
- Establishment
- NUBIOLA, LLC
- Site address
- 6369 PEACHTREE STREET
- City
- NORCROSS
- State
- GA
- ZIP
- 30071
- Mailing
- 6369 PEACHTREE STREET, NORCROSS, GA 30071
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325131
- Employees
- 25
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.22 A01
- Issued
- Abate by
- Penalty
- Initial $3000.00 · Current $2000.00 Reduced
1520
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept in a sanitary condition: On or about November 22, 2013: Employees working in the facility located at 6369 Peachtree Street are exposed to surface contact hazards from the accumulation of contaminants such as, but not limited to iron oxide. Surface wipe sampling was conducted on November, 22 and December 12, 2013. These areas had the following accumulation of iron oxide per 100 cm2: (a) Sample #13-42, Top of file cabinet in Lab Supervisor's Office: 388.11 micrograms (b) Sample #13-36, On top of refrigerator in the break-room: 286.91 micrograms (c) Sample #13-34, Top right side of stereo in break-room: 276.84 micrograms (d) Sample #13-39, Workstation tabletop near the blending area: 179.46 micrograms (e) Sample #13-40, Workstation in lower level of blending area: 134.94 micrograms (f) Sample #13-38, Top right side of file cabinet in S&R office: 122.69 micrograms (g) Sample #13-41, Tabletop near the weigh scale in lab: 116.20 micrograms (h) Sample #13-35, On top of counter in front of small microwave: 96.79 micrograms
Recent events (2)
- — I (S) $2000
- — Z (S) $3000
1910.1027 F02 I
- Issued
- Abate by
- Penalty
- Initial $4000.00 · Current $3000.00 Reduced
C141
General-duty citation text
29 CFR 1910.1027(f)(2)(i): When the permissible exposure limit (PEL) was exceeded, the employer did not establish and implement a written compliance program to reduce employee exposure to cadmium to or below the PEL by means of engineering and work practice controls: On or about November 22, 2013: Employees working in the blending area are exposed to air contaminants such as, but not limited to cadmium. Air sampling was conducted on employees December 12, 2013. One employee was over the cadmium permissible exposure limit (PEL) of 5 micrograms per cubic meter of air by more than nine times the limit. The employer had not established and implemented within their written program, engineering and work practice procedures to reduce employee expose to cadmium.
Recent events (2)
- — I (S) $3000
- — Z (S) $4000
1910.1027 J01
- Issued
- Abate by
- Penalty
- Initial $4000.00 · Current $3000.00 Reduced
C141
General-duty citation text
29 CFR 1910.1027(j)(1): The employer did not provide clean change rooms, hand washing facilities, showers, and lunchroom facilities that complied with 29 CFR 1910.141 for employees whose airborne exposure to cadmium was above the permissible exposure limit (PEL): On or about November 22, 2013: Employees working in the blending area are exposed to air contaminants such as, but not limited to cadmium. Air sampling was conducted on employees December 12, 2013 and the employee conducting the cadmium blending process was exposed at an 8 hour time weighted average (8hr TWA) of 46 micrograms per cubic meter of air, which is more than nine times the permissible exposure limit. The employer does not provide a change room for employees conducting this process.
Recent events (2)
- — I (S) $3000
- — Z (S) $4000
1910.1027 J03 I
- Issued
- Abate by
- Penalty
- Initial $4000.00 · Current $3000.00 Reduced
C141
General-duty citation text
29 CFR 1910.1027(j)(3)(i): The employer did not ensure that employees exposed to cadmium above the permissible exposure limit (PEL) showered during the end of the work shift: On or about November 22, 2013: Employees working in the blending area are exposed to air contaminants such as, but not limited to cadmium. Air sampling was conducted on employees December 12, 2013. The employee conducting cadmium blending was over the cadmium permissible exposure limit (PEL) of 5 micrograms per cubic meter of air, by more than nine times the limit. The employer did not require employees conducting cadmium blending to shower at the end of their work shift.
Recent events (2)
- — I (S) $3000
- — Z (S) $4000
1910.1027 K01
- Issued
- Abate by
- Penalty
- Initial $4000.00 · Current $0.00 Reduced
C141
General-duty citation text
29 CFR 1910.1027(k)(1): Surfaces were not maintained as free as practicable of accumulations of cadmium: On or about November 22, 2013: Employees working in the production area are exposed to surface contact hazards from the accumulation of cadmium. Surface wipe sampling was conducted on November, 22 and December 12, 2013. The following areas had an accumulation of cadmium: (a) Sample #13-39, Work station tabletop near the blending area: 23.03 micrograms (b) Sample #13-42, Top of file cabinet in Lab Supervisor's Office: 19.85 micrograms (c) Sample #13-41, Tabletop next to the weigh scale in lab area: 15.88 micrograms (d) Sample #13-34, Top right side of stereo in break-room: 8.37 micrograms (e) Sample #13-36, On top of refrigerator in the break-room: 6.41 micrograms
Recent events (2)
- — I (S) $0
- — Z (S) $4000
1910.134 C02 II
- Issued
- Abate by
- Penalty
- Initial $38500.00 · Current $7000.00 Reduced
1520C141
General-duty citation text
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily, cleaned, stored, and maintained that respirator so that its use does not present a health hazard to the user: On or about November 22, 2013: Employees working in the blending area are exposed to air and surface contaminants such as, but not limited to cadmium and iron oxides. Employees 3M half face respirators are not thoroughly cleaned and voluntary use is not addressed in the respiratory protection program. Surface sampling was conducted on employees respirators on December 12, 2013 with the following results: (a) Sample #13-45 - Inside face shield of Employee 1 half face respirator - 4.84 micrograms, cadmium (b) Sample #13-45 - Inside face shield of Employee 1 half face respirator - 80.62 micrograms, iron oxide (c) Sample #13-47 - Inside face shield of Employee 2 half face respirator - 3.00 micrograms, cadmium (d) Sample #13-47 - Inside face shield of Employee 2 half face respirator - 152.38 micrograms, iron oxide
Recent events (2)
- — I (S) $7000
- — Z (W) $38500
1910.134 H01 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $7000.00
C141
General-duty citation text
29 CFR 1910.134(h)(1)(i): Respirators issued for the exclusive use of an employee were not cleaned and disinfected as often as necessary to be maintained in a sanitary condition: On or about November 22, 2013: Employees working in the blending area are exposed to air and surface contaminants such as, but not limited to cadmium. Employee respirators are not thoroughly cleaned and disinfected prior to storage. Surface sampling was conducted on employee respirators on December 12, 2013 with the following results: Sheet/Sample # 166528/13-46 - Inside face shield of PAPR of employee 2 - 89.11 micrograms, cadmium
Recent events (2)
- — I (S) $7000
- — Z (W) $0
1910.134 K05 I
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(k)(5)(i): Retraining was not conducted when changes in the workplace or the type of respirator rendered previous training obsolete: On or about November 22, 2013: Employees working in the blending area are exposed to air and surface contaminants such as, but not limited to cadmium. Employees were provided with new powered air supplied respirators in 2013, but were not trained on the new respirators until April 10, 2014.
Recent events (2)
- — I (W) $0
- — Z (W) $0
1910.1027 C
- Issued
- Abate by
- Penalty
- Initial $38500.00 · Current $0.00 Reduced
C141
General-duty citation text
29 CFR 1910.1027(c): The employer did not ensure that no employee was exposed to an airborne concentration of cadmium in excess of five micrograms per cubic meter of air (5ug/m3), calculated as an eight-hour time-weighted average (TWA): On or about November 22, 2013: Employees working in the blending area are exposed to air contaminants such as, but not limited to cadmium. Air sampling was conducted on employees December 12, 2013. The employee conducting the cadmium blending was over the cadmium permissible exposure limit (PEL) of 5 micrograms per cubic meter of air by more than nine times the limit. Sample # 166497: 8 hour time weighted average (8hr TWA) = 46 micrograms per cubic meter
Recent events (2)
- — I (W) $0
- — Z (W) $38500
1910.1027 D05 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
C141
General-duty citation text
29 CFR 1910.1027(d)(5)(ii): Whenever the monitoring results indicated that employee exposure exceeded the permissible exposure limit (PEL), the employer did not include in the written notice a description of the corrective action being taken by the employer to reduce employee to or below the PEL: On or about November 22, 2013: Employees working in the production area are exposed to air and surface contact hazards from the accumulation of cadmium. Air sampling was conducted on December 12, 2013.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 325131)
TAMAQUA, PA—2022-05-11 00:00:00
SILBERLINE MANUFACTURING COMPANY INC.
TAMAQUA, PA—2022-05-11 00:00:00
SILBERLINE MANUFACTURING COMPANY INC.
INDIANAPOLIS, IN—2020-11-19 00:00:00
111530 - NAKOMA PRODUCTS
SPRINGFIELD, IL—2020-05-19 00:00:00
SOLOMON COLORS, INC.
NORTH CHARLESTON, SC—2019-12-03 00:00:00
74341 - LANXESS CORPORATION
More inspections in GA
GREENSBORO, GA—2026-07-16
PURE BEAUTY FARMS, INC.
FOREST PARK, GA—2026-07-16
POLYNT COMPOSITES USA INC.
AUGUSTA, GA—2026-07-16
GF CASTING SOLUTIONS AUGUSTA, LLC
CHAMBLEE, GA—2026-07-16
U.S. DEPARTMENT OF TREASURY
DECATUR, GA—2026-07-15
PALLETS ACQUISITION LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339503120.