OSHA Inspection: MATEUSZ STASZEL

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MATEUSZ STASZEL in 18 MEADOWOOD ESTATES, LONG GROVE, IL 60047 (NAICS 238130). OSHA activity number 339504029.

Watch Mateusz Staszel — free Get an email when a new federal OSHA severe-injury report for Mateusz Staszel is published. One employer, no account, unsubscribe in one click.
Establishment
MATEUSZ STASZEL
Site address
18 MEADOWOOD ESTATES
City
LONG GROVE
State
IL
ZIP
60047
Mailing
4960 N. MARMORA AVE., CHICAGO, IL 60634
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
3
Ownership type
A

8 citations on file for this inspection.

1926.304 F

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2400.00 · Current $1200.00 Reduced
29 CFR 1926.304(f): Section 4.1.2(a) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed rip saws were not guarded by an automatically adjusting hood which completely encloses that portion of the saw above the table and above the material being cut:      a) A Royobi table saw was not equipped with a blade guard when used to rip lumber.      In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2400

1926.304 F

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.304(f): Section 4.1.2(b) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed rip saws were not equipped with a spreader to prevent material from squeezing the saw or being thrown back on the operator:   a) A Royobi table saw was not equipped with a spreader when used to rip lumber.   In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.304 F

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.304(f): Section 4.1.2(c) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed rip saws did not have non-kickback fingers on dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator:    a) A Royobi table saw was not equipped with non-kickback fingers or dogs when used to rip lumber.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 E01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1400.00 Reduced
29 CFR 1926.451(e)(1): Safe access was not provided to scaffold platforms when the platforms were more than 2 feet (0.6 m) above or below a point of access:           a) Employees were not provided with safe access to a scaffolding platform from which they were required to work at an elevation of approximately 16 feet.          In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1926.451 G01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section:   a) Employees were exposed to the hazard of falling approximately 16 feet while working from a scaffold platform spanned between a ladder and the roof of the building.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 B03

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(b)(3): The front edge of all platforms was not 14 inches (36 cm) or less from the face of the work, and no guardrail systems were erected along the front edge and/or no personal fall arrest systems were used in accordance with paragraph (g) of this section to protect employees from falling:   a) The distance from the face for work conducted from a scaffolding platform was about 3 feet.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B13

Serious Gravity 10 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1400.00 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b):       a) Employees were exposed to the hazard of falling while performing carpentry work from a 12/12 pitched roof having a ground to eave height of approximately 13 feet without the use of fall protection.     b) Employees were exposed to the hazard of falling from unprotected window openings on the second story of the building.       In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1926.503 B01

Other-than-serious 3 instances 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.503(b)(1): The employer did not verify fall protection training by preparing a written certification record:       a) The employer did not prepare written certification records related to employee fall protection training.      In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).