WASHINGTON, DC —
OSHA Inspection: JACK STONE SIGNS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JACK STONE SIGNS in 433 MASSACHUSETTS AVENUE, NW, WASHINGTON, DC 20003 (NAICS 238210). OSHA activity number 339512303.
Where did this inspection happen?
- Establishment
- JACK STONE SIGNS
- Site address
- 433 MASSACHUSETTS AVENUE, NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20003
- Mailing
- 3131 PENNSY DRIVE, LANDOVER, MD 20785
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- Employees
- 2
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.95 A
- Issued
- Penalty
- Initial $2800.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1926.95(a): Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, and maintained in a sanitary and reliable condition wherever it is necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact. a) Exterior Front Entrance Canopy - A supervisor was observed drilling into a brick mortar joint using a portable battery operated drill, and not wearing safety glasses, on or about 12/05/2013.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1926.501 B01
- Issued
- Penalty
- Initial $4200.00 · Current $2100.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a) Exterior Front Entrance - Employees were observed standing on a steel canopy that measured 3 ft. wide by 5 ft - 1inch long, drilling holes into brick mortar joints and exposed to a 9 ft. 8 inch fall hazard, on or about 12/05/2013.
Recent events (2)
- — I (S) $2100
- — Z (S) $4200
1926.503 A01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) Exterior Front Entrance - Employees were not provided fall hazard recognition training as evidenced by employees standing on a 3 ft. wide by 5 ft. 1 inch long steel canopy drilling holes into a brick mortar joint and exposed to a 9 ft. 8 inch fall hazard, on or about 12/05/2013. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B01
- Issued
- Penalty
- Initial $4200.00 · Current $2100.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): A portable ladder was used for access to an upper landing surface, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when an extension is not possible because of the ladder's length, the ladder was not secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, was not provided to assist employees in mounting and dismounting the ladder. In a) Exterior Front Entrance - Employees were observed using an 8 ft. portable step ladder to gain access to the top of a steel canopy. The top of the ladder was 25 inches below the landing surface, on or about 12/05/2013.
Recent events (2)
- — I (S) $2100
- — Z (S) $4200
1926.1053 B13
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: a) Exterior Front Entrance - Employees were observed standing on the top of an 8 ft. portable step ladder while gaining access to the top of a steel canopy, on or about 12/05/2013.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 238210)
PARKVILLE, MD—2026-07-15
THE POWER SOURCE, INC.
SOUTH BARRINGTON, IL—2026-07-15
EDGE ELECTRICAL SYSTEMS, LLC
LAYTON, UT—2026-07-14
LYNN WOODWARD ELECTRIC LLC
BRIDGEPORT, WV—2026-07-14
INFINITY ELECTRIC & SERVICE COMPANY, LLC
ANNAPOLIS, MD—2026-07-14
J.M. MULLEN ELECTRICAL SERVICES, INC.
More inspections in DC
WASHINGTON, DC—2026-06-30
U.S. DEPARTMENT OF AGRICULTURE
WASHINGTON, DC—2026-06-16
MACY'S
WASHINGTON, DC—2026-06-02
RIGO MULTISERVICES
WASHINGTON, DC—2026-06-02
DDC CPL LLC
WASHINGTON, DC—2026-06-02
DDC CPL LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339512303.