Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: LOWE'S OF RUSTON

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of LOWE'S OF RUSTON in 809 MORRISON DRIVE, RUSTON, LA 71270 (NAICS 444110). OSHA activity number 339513335.

Watch Lowe'S OF Ruston — free Get an email when a new federal OSHA severe-injury report for Lowe'S OF Ruston is published. One employer, no account, unsubscribe in one click.
Establishment
LOWE'S OF RUSTON
Site address
809 MORRISON DRIVE
City
RUSTON
State
LA
ZIP
71270
Mailing
MAIL CODE: A2ELP 1000 LOWE'S BLVD, MOORESVILLE, NC 28117
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
444110
Employees
137
Ownership type
A

4 citations on file for this inspection.

1910.37 B02

Other-than-serious 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":  On or about 11/21/2013, at 809 Morrison Drive, Ruston, LA, employees were accessing an electrical room without the exit door being marked as an exit.
Recent events (1)
  • — Z (O) $0

1910.178 P01

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been  taken out of service until restored to safe operating condition(s):  On or about 11/21/2013, at 809 Morrison Drive, Ruston, LA, an employee was operating a Yale model #GLP-50, serial #B875B03548D powered industrial truck with a missing rear light.
Recent events (1)
  • — Z (O) $0

1910.303 G01 II

Other-than-serious 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(g)(1)(ii): Working space required by this standard shall not be used for storage. When normally enclosed live parts are exposed for inspection or servicing, the working space, if in a passageway or general open space, shall be suitably guarded:  On or about 11/21/2013, at 809 Morrison, Ruston, LA, employees were using an main electrical room for storage for a ice machine, barbeque pit, and a storage container.
Recent events (1)
  • — Z (O) $0

1910.305 B02 I

Other-than-serious 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:     On or about 11/21/2013, at 809 Morrison Drive, Ruston, LA, employees were accessing the main electrical closet to the facility with an electrical junction box without a cover.
Recent events (1)
  • — Z (O) $0

OXYCHEM