Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: WORRYNOUGHT KENNELS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of WORRYNOUGHT KENNELS, INC. in 3102 STATE ROUTE 110, DE SOTO, MO 63020 (NAICS 541940). OSHA activity number 339514796.

Watch Worrynought Kennels, INC. — free Get an email when a new federal OSHA severe-injury report for Worrynought Kennels, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3102 STATE ROUTE 110
City
DE SOTO
State
MO
ZIP
63020
Mailing
3102 STATE ROUTE 110, DE SOTO, MO 63020
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
541940
Employees
5
Ownership type
A

8 citations on file for this inspection.

1910.23 A08 II

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.23(a)(8)(ii): Every floor hole into which persons could accidentally walk was not guarded by a floor hole cover of standard strength and construction:    Dog Kennel by Grooming area:  Employees were exposed to a trip hazard where a floor hole measuring 2 1/2 inches in its least dimension was covered with damaged duct tape.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.138 A

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.138(a): The employer did not select and require employee(s) to use appropriate hand protection when employees' hands were exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasion; punctures; chemical burns; thermal burns; and harmful temperature extremes:    Exit Door: Employees were exposed to severe cut hazards where damaged glass panes were not repaired and the employees were not provided personal protective equipment for the hands.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B07 IV

Serious Gravity 5 3 instances 3 exposed
Issued
Abate by
Penalty
Initial $1700.00 · Current $170.00 Reduced
29 CFR 1910.303(b)(7)(iv): There were damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemical action or overheating:   Basement wall (Grooming area): Employees were exposed to imminent danger where a damaged duplex receptacle outlet with exposed internal wiring and a duplex receptacle with a broken ground pin embedded in the ground pin slot were used to supply power to portable dryers used where there was moisture.    Back Room: Damaged electrical equipment was held to the ceiling using a conductive duct tape.     Back Door area of the Kennels area: Damaged electrical equipment was used to supply power to a flexible cord set (extension cord).
Recent events (2)
  • — I (S) $170
  • — Z (S) $1700

1910.303 B08 I

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(b)(8)(i): Electrical equipment was not firmly secured to the surface on which it was mounted:    Back Room: An electrical socket with an incandescent bulb was not secured to the surface to which it was attached.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G02 I

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1700.00 · Current $170.00 Reduced
29 CFR 1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by approved cabinets or forms of approved enclosures:     Kennels:  Employees were exposed to imminent danger from electrical hazards created by exposed live electrical parts.
Recent events (2)
  • — I (S) $170
  • — Z (S) $1700

1910.304 G05

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1700.00 · Current $170.00 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:      Upper Level, Training area: Employees were exposed to imminent danger where they used an electrical receptacle outlet which did not have ground connections to supply power to a vacuum cleaner.  Both the receptacle outlet and its face plate (cover) were energized (hot).    Grooming area: (a) A hand dryer, Metro Air Force Commander, used for grooming purposes had the ground pin dislodged.                          (b) An Oster Dryer which originally had a three-prong attachment plug was replaced with a two-prong attachment plug.
Recent events (2)
  • — I (S) $170
  • — Z (S) $1700

1910.305 B02 I

Serious Gravity 5 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:   Floor of the Cash Register area: A duplex receptacle outlet on the floor to which a cash register and phone systems were connected did not have a faceplate.  Grooming area: A wall mounted duplex receptacle outlet did not have a faceplate.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G02 II

Serious Gravity 5 1 instance 3 exposed
Issued
Penalty
Initial $1700.00 · Current $170.00 Reduced
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap:     Lunch Room area: Employees were exposed to imminent danger where power cord of a refrigerator which was used daily was spliced.  The spliced power cord was in contact with metal parts of the refrigerator.
Recent events (2)
  • — I (S) $170
  • — Z (S) $1700

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339514796.