ALTOONA, WI —
OSHA Inspection: THE SLICK UP CENTER, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of THE SLICK UP CENTER, INC. in 820 NORTH HILLCREST PARKWAY, ALTOONA, WI 54720 (NAICS 423120). OSHA activity number 339518037.
Where did this inspection happen?
- Establishment
- THE SLICK UP CENTER, INC.
- Site address
- 820 NORTH HILLCREST PARKWAY
- City
- ALTOONA
- State
- WI
- ZIP
- 54720
- Mailing
- 820 NORTH HILLCREST PARKWAY, ALTOONA, WI 54720
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423120
- Employees
- 8
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.106 D03 II
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $720.00 Reduced
General-duty citation text
29 CFR 1910.106(d)(3)(ii): Flammable liquid storage cabinet(s) were not labeled in conspicuous lettering, "Flammable - Keep Fire Away": (a) Flammable cabinet; the employer provides a wooden flammable cabinet that does not have any signs or postings.
Recent events (2)
- — I (S) $720
- — Z (S) $1200
1910.106 D03 II B
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.106(d)(3)(ii)(b): The bottom, sides, and/or tops of wooden cabinets were not constructed of an approved grade of plywood at least 1 inch in thickness, that would prevent it from breaking down or delaminating under fire conditions: (a) Flammable cabinet; the employer provides a wooden flammable cabinet that is not in compliance with this standard. Such as, but not limited to the following: All of the joints are not rabbited and fastened in two directions with flathead screws, It is not constructed of at least 1 inch of approved grade plywood, More than one door is used and there is no rabbited overlap.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.106 D04 IV
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.106(d)(4)(iv): 29 CFR 1910.106(d)(4)(iv): Ventilation. Every inside storage room was not provided with either a gravity or a mechanical exhaust ventilation system. Such system was not designed to provide for a complete change of air within the room at least six times per hour. (a) Storage room; the employer stores flammable products in an inside storage room where there is no exhaust ventilation.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 C02 II
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $720.00 Reduced
General-duty citation text
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user: (a) Throughout the facility; the employer failed to establish or implement the elements of a written respiratory protection program to ensure employees are medically able to voluntarily use a respirator. The employer also failed to ensure the respirator is cleaned, stored and maintained so as to not present a health hazard to the user.
Recent events (2)
- — I (S) $720
- — Z (S) $1200
1910.134 D01 III
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminants chemical state and physical form: (a) Throughout the facility; the employer failed to evaluate employee exposure to respiratory hazard(s): Such as, but not limited to the spray in truck bed liner product called Gardit.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 E01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employees ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (a) Throughout the facility; the employer failed to provide a medical evaluation to employees prior to requiring them to use respiratory protection in the workplace.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 423120)
KENT, WA—2026-06-25
WA317991799 - PARKER HANNIFIN CORP
OMAHA, NE—2026-06-24
A.C. NELSEN RV WORLD
POMPANO BEACH, FL—2026-06-15
PARTS AUTHORITY LLC
COLUMBUS, IN—2026-06-12
KAMIC CORPORATION
GAMBRILLS, MD—2026-05-28
TRI-STATE BATTERY WAREHOUSE
More inspections in WI
MUSCODA, WI—2026-07-10
SCOT INDUSTRIES, INC