Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: THE SLICK UP CENTER, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of THE SLICK UP CENTER, INC. in 820 NORTH HILLCREST PARKWAY, ALTOONA, WI 54720 (NAICS 423120). OSHA activity number 339518037.

Watch THE Slick UP Center, INC. — free Get an email when a new federal OSHA severe-injury report for THE Slick UP Center, INC. is published. One employer, no account, unsubscribe in one click.
Site address
820 NORTH HILLCREST PARKWAY
City
ALTOONA
State
WI
ZIP
54720
Mailing
820 NORTH HILLCREST PARKWAY, ALTOONA, WI 54720
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423120
Employees
8
Ownership type
A

6 citations on file for this inspection.

1910.106 D03 II

Serious Gravity 1 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $720.00 Reduced
29 CFR 1910.106(d)(3)(ii): Flammable liquid storage cabinet(s) were not labeled in conspicuous lettering, "Flammable - Keep Fire Away":      (a) Flammable cabinet; the employer provides a wooden flammable cabinet that does not have any signs or postings.
Recent events (2)
  • — I (S) $720
  • — Z (S) $1200

1910.106 D03 II B

Serious Gravity 1 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.106(d)(3)(ii)(b): The bottom, sides, and/or tops of wooden cabinets were not constructed of an approved grade of plywood at least 1 inch in thickness, that would  prevent it from breaking down or delaminating under fire conditions:   (a) Flammable cabinet; the employer provides a wooden flammable cabinet that is not in compliance with this standard. Such as, but not limited to the following: All of the joints are not rabbited and fastened in two directions with flathead screws, It is not constructed of at least 1 inch of approved grade plywood, More than one door is used and there is no rabbited overlap.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.106 D04 IV

Serious Gravity 1 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.106(d)(4)(iv): 29 CFR 1910.106(d)(4)(iv): Ventilation. Every inside storage room was not provided with either a gravity or a mechanical exhaust ventilation system. Such system was not designed to provide for a complete change of air within the room at least six times per hour.   (a) Storage room; the employer stores flammable products in an inside storage room where there is no exhaust ventilation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 C02 II

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $720.00 Reduced
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user:      (a) Throughout the facility; the employer failed to establish or implement the elements of a written respiratory protection program to ensure employees are medically able to voluntarily use a respirator.  The employer also failed to ensure the respirator is cleaned, stored and maintained so as to not present a health hazard to the user.
Recent events (2)
  • — I (S) $720
  • — Z (S) $1200

1910.134 D01 III

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminants chemical state and physical form:  (a) Throughout the facility; the employer failed to evaluate employee exposure to respiratory hazard(s):  Such as, but not limited to the spray in truck bed liner product called Gardit.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 E01

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employees ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  (a)  Throughout the facility; the employer failed to provide a medical evaluation to employees prior to requiring them to use respiratory protection in the workplace.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339518037.