Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: MICA CRANE SERVICES, INC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of MICA CRANE SERVICES, INC. in WEST W.J. BOAZ, SAGINAW, TX 76179 (NAICS 238990). OSHA activity number 339528523.

Watch Mica Crane Services, INC. — free Get an email when a new federal OSHA severe-injury report for Mica Crane Services, INC. is published. One employer, no account, unsubscribe in one click.
Site address
WEST W.J. BOAZ
City
SAGINAW
State
TX
ZIP
76179
Mailing
3401 NORTH SYLVANIA AVE SUITE 117, FORT WORTH, TX 76111
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238990
Employees
5
Ownership type
A

4 citations on file for this inspection.

1926.1404 Q05 I

Serious Gravity 5 2 instances 1 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $960.00 Reduced
29 CFR 1926.1404(q)(5)(i): The outrigger and stabilizer blocking did not meet the requirements in paragraphs (h)(2) and (h)(3) of this section.    On or about December 19, 2013, during setup assembly of the Manitex truck mounted crane, the employer did not ensure the blocking material was sufficient to sustain the loads and maintain stability exposing employees to struck by and crushed by hazards:    a) under the rear drivers side outrigger, the employer used Oriented Strand Board (OSB) sheathing as a base under the blocking;    b) on the right front outrigger, the stabilizer pad and blocking was not placed on level ground to prevent movement or collapsing.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1926.1412 D01 XI

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1200.00 Reduced
29 CFR 1926.1412(d)(1)(xi): The employer failed to inspect equipment for level position within the tolerances specified by the equipment manufacturer's recommendations, both before each shift and after each move and setup:    On or about December 19, 2013, during setup assembly and during each movement of the Manitex truck mounted crane, the employer did not ensure the equipment was inspected for level positioning and maintaining a level position during operations exposing employees to the hazards of roll-over and struck-by hazards.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1926.1415 A01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $0.00 Reduced
29 CFR 1926.1415(a)(1)(ii): The crane was being operated with a built-in level indicator that was not working properly and was not tagged out.    On or about December 19, 2013, the employer did not ensure the Manitex truck mounted crane built-in level indicator was functioning properly and either tagged out or removed; or that the crane was leveled properly according to the built-in level indicator prior to operation exposing employees to roll-over and struck-by hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1600

1926.1433 D06

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $400.00 · Current $240.00 Reduced
29 CFR 1926.1433(d)(6): An accessible fire extinguisher was not on the equipment.    On or about December 19, 2014, the employer did not ensure a fire extinguisher was readily available in the cab of the crane exposing employees to fire hazards.
Recent events (2)
  • — I (O) $240
  • — Z (O) $400

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339528523.