MOULTON, TX —
OSHA Inspection: HUNTER HAULING, LLC
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of HUNTER HAULING, LLC in 526 S LAVACA, MOULTON, TX 77975 (NAICS 213112). OSHA activity number 339530743.
Where did this inspection happen?
- Establishment
- HUNTER HAULING, LLC
- Site address
- 526 S LAVACA
- City
- MOULTON
- State
- TX
- ZIP
- 77975
- Mailing
- 1048 TEXAN TRAIL, GRAPEVINE, TX 76051
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213112
- Employees
- 80
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.146 C04
- Issued
- Abate by
- Penalty
- Initial $4900.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.146(c)(4): When the employer decided that its employees would enter permit spaces, the employer did not develop and implement a written permit space entry program that complied with 29 CFR 1910.146: At this location, employees entered into a tanker vessel to make repairs and the employer did not have a written permit-required confined space program. In the alternative: 29CFR1910.146 (c)(3)
Recent events (2)
- — I (S) $0
- — Z (S) $4900
1910.146 D04 I
- Issued
- Abate by
- Penalty
- Initial $4900.00 · Current $4900.00
General-duty citation text
29 CFR 1910.146(d)(4)(i): Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not provide, at no cost to the employees, testing and monitoring equipment needed to comply with 29 CFR 1910.146(d): At this establishment, the employees performed maintenance inside tanker vessels and were not provided with four gas meters to perform atmospheric testing to determine safe entry.
Recent events (2)
- — I (S) $4900
- — Z (S) $4900
1910.146 D04 II
- Issued
- Abate by
- Penalty
- Initial $4900.00 · Current $4900.00
General-duty citation text
29 CFR 1910.146(d)(4)(ii): Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not provide, at no cost to the employees, ventilating equipment needed to obtain acceptable entry conditions: At this worksite, in the trailer vessels, the employer did not provide any form of ventilation equipment for its employees while they performed maintenance inside the trailer vessel.
Recent events (2)
- — I (S) $4900
- — Z (S) $4900
1910.146 E01
- Issued
- Abate by
- Penalty
- Initial $4900.00 · Current $4900.00
General-duty citation text
29 CFR 1910.146(e)(1): Before entry was authorized, the employer did not document the completion of measures required by 29 CFR 1910.146(d)(3) by preparing an entry permit: At this worksite, the employer did not have documentation of an authorized entry into a confined space work area.
Recent events (2)
- — I (S) $4900
- — Z (S) $4900
More inspections in this industry (NAICS 213112)
SEILING, OK—2026-06-26
GORE ENERGY
SCIO, OH—2026-06-25
AMPRO WELL SERVICES, LLC
MIDLAND, TX—2026-06-23
JAT PARTNER LOGISTICS LLC
STUART, OK—2026-06-18
HEARTLAND ENERGY SOLUTIONS, LLC
GARDEN CITY, TX—2026-06-17
EBENEZER COMPANIES LLC
More inspections in TX
SPRING, TX—2026-07-10
DORSTENER WIRE TECH INC.
FORT WORTH, TX—2026-07-10
RC PROFESSIONAL ROOFING OF TEXAS LLC
CYPRESS, TX—2026-07-10
FEDERICO CARVAJAL GARCIA
SAN ANTONIO, TX—2026-07-10
ED LONG'S METAL WORKS
SAN ANTONIO, TX—2026-07-09
WAREHOUSE RACK COMPANY, LP
Source