Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JC STONE, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JC STONE, INC. in 539 ROCKLAND ROAD, JEFFERSON, ME 04348 (NAICS 327991). OSHA activity number 339538738.

Watch JC Stone, INC. — free Get an email when a new federal OSHA severe-injury report for JC Stone, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
JC STONE, INC.
Site address
539 ROCKLAND ROAD
City
JEFFERSON
State
ME
ZIP
04348
Mailing
539 ROCKLAND ROAD, JEFFERSON, ME 04348
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327991
Employees
20
Ownership type
A

4 citations on file for this inspection.

1910.37 A03

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $1360.00 · Current $680.00 Reduced
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed:   At the Facility - An exit door is obstructed by a cord running in front of it and, when opened, the exit route leads into the roped off back side of the contour wire saw.
Recent events (2)
  • — I (S) $680
  • — Z (S) $1360

1910.37 B05

Serious Gravity 1 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g. closet):  Production Area - The door which leads to the Giga saw room had no sign ndicating that it was "not an exit".
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.184 D

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $1700.00 · Current $850.00 Reduced
29 CFR 1910.184(d): Damaged or defective sling(s) were not immediately removed from service:   Production Area:  A defective sling, one with the "red" thread showing, had not been taken out of service.
Recent events (2)
  • — I (S) $850
  • — Z (S) $1700

1910.335 B01

Other-than-serious 2 instances 10 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.335(b)(1): 29 CFR 1910.335(b)(1):   Safety signs, safety symbols, or accident prevention tags were not used where necessary to warn employees about electrical hazards which may endanger them:   Production Area - There were no arc flash warning signs on the electrical panels in the room where the contour wire saw is located.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339538738.