Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DENOBLE CONSTRUCTION LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DENOBLE CONSTRUCTION LLC in 6778 FLAMETREE DRIVE, FAYETTEVILLE, NY 13066 (NAICS 238130). OSHA activity number 339542458.

Watch Denoble Construction LLC — free Get an email when a new federal OSHA severe-injury report for Denoble Construction LLC is published. One employer, no account, unsubscribe in one click.
Site address
6778 FLAMETREE DRIVE
City
FAYETTEVILLE
State
NY
ZIP
13066
Mailing
7284 HIGHBRIDGE ROAD, FAYETTEVILLE, NY 13066
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
3
Ownership type
A

6 citations on file for this inspection.

1926.451 A06

Serious Gravity 5 2 instances 3 exposed
Issued
Penalty
Initial $1360.00 · Current $816.00 Reduced
29 CFR 1926.451(a)(6): Scaffolds were not designed by a qualified person:  a) 6778 Flametree Drive residential Roof - On or about 10 January, 2014 - Employees were using a job built supported scaffold that was not designed by a qualified person.
Recent events (2)
  • — I (S) $816
  • — Z (S) $1360

1926.451 B02

Serious Gravity 5 2 instances 3 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(b)(2): Except as provided in paragraphs (b)(2)(i) and (b)(2)(ii) of this section, each scaffold platform and/or walkway was not at least 18 inches (46 cm) wide:  a) 6778 Flametree Drive residential Roof - On or about 10 January, 2014 - Employees were using a job built supported scaffold with the walkways were not at least 18 inches wide.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.454 A

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards.  a) 6778 Flametree Drive residential Roof  On or about 10 January, 2014  Employees were using a job built supported scaffold where the walkways were not at least 18 inches wide, where the scaffold was not designed or built under the direction of a qualified person, and where the workers were not trained on the safe use of that scaffold.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1053 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $1360.00 · Current $816.00 Reduced
29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladders length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigied support that will not deflect, and/or a grasping device was not provided to assist emmployees in mounting and dismounting the ladder.  a) 6778 Flametree Drive residential Roof  On or about 10 January, 2014  Employees were using a ladder to access the upper landing surface of the scaffold that did not extend a minimum of 3 feet above the landing surface.
Recent events (2)
  • — I (S) $816
  • — Z (S) $1360

1926.403 B02

Other-than-serious 1 instance 3 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:  a) 6778 Flametree Drive residential Roof  On or about 10 January, 2014  Employees were using a relocatable power tap on the construction site that was not in accordance with the manufacturers and UL listing requirements.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.405 G02 IV

Other-than-serious 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:   a) 6778 Flametree Drive residential Roof  On or about 10 January, 2014  Employees were using a circular saw that did not have strain relief provided to prevent pull from being directly transmitted to joints or terminal screws.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339542458.