LEHIGHTON, PA —
OSHA Inspection: DONALD B REMMEY INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DONALD B REMMEY INC in 573 MILL RD, LEHIGHTON, PA 18235 (NAICS 321920). OSHA activity number 339542912.
Where did this inspection happen?
- Establishment
- DONALD B REMMEY INC
- Site address
- 573 MILL RD
- City
- LEHIGHTON
- State
- PA
- ZIP
- 18235
- Mailing
- 573 MILL RD, LEHIGHTON, PA 18235
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321920
- Employees
- 39
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.213 H01
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $3000.00 Reduced
General-duty citation text
29 CFR 1910.213(h)(1): The sides of the lower exposed portion of the blade were not guarded to the full diameter of the blade by a device that automatically adjusts itself to the thickness of the stock and remains in contact with stock being cut to give maximum protection possible for the operation being performed: a) Hand Assembly Area: The self adjusting guard on an Original Radial Arm Saw had been removed exposing the operator to the rotating blade and an amputation hazard, on or about January 10, 2014. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $3000
- — Z (S) $3500
1910.219 D01
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulleys, with parts of which are seven (7) feet or less from the floor or working platform, were not guarded in accordance with the standards specified in paragraphs (m) and (o) of this section: a) Maintenance Shop: A large belt driven pulley attached to the wall above the Southbend lathe was not enclosed by a guard exposing workers to a nip point hazard, on or about January 10, 2014. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (S) $3500
1910.219 E03 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.219(e)(3)(i): Vertical and inclined belts were not enclosed by a guard conforming to standards in paragraphs (m) and (o) of this section: a) Maintenance Shop: A pair of belts on the Southbend lathe were not enclosed by a guard exposing workers to the running belts, on or about January 10, 2014. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.305 G02 III
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $3000.00 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief is provided that will prevent pulls from being directly transmitted to joints or terminal screws: a) Production Area: Strain relief was not provided for the blow off switch on the Viking pallet stacker exposing workers to an electric shock hazard, on or about January 10, 2014. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $3000
- — Z (S) $3500
1910.147 C06 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The employer did not certify that the periodic inspections have been performed: a) Lehighton Facility: The employer failed to document that the required periodic inspections of the lockout procedure had been performed, on or about January 10, 2014. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 G01 I B
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(g)(1)(i)(B): The width of working space in front of electrical equipment was not the width of the equipment or 30 inches, whichever is greater: a) Saw Cutting Building: Access to a pair of power disconnect panel boxes was blocked by a conveyor, on or about January 10, 2014. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at DONALD B REMMEY INC
LEHIGHTON, PA—2025-08-11
DONALD B REMMEY INC
BEAVER SPRINGS, PA—2025-07-09
DONALD B REMMEY INC
BEAVER SPRINGS, PA—2020-01-16 00:00:00
DONALD B REMMEY INC
LEHIGHTON, PA—2018-11-30 00:00:00
DONALD B. REMMEY, INC.
LEHIGHTON, PA—2017-01-17 00:00:00
DONALD B. REMMEY, INC.
View DONALD B REMMEY INC's full OSHA safety record →
More inspections in this industry (NAICS 321920)
FITCHBURG, MA—2026-07-10
KELLEY WOOD PRODUCTS, INC.
WASHINGTON COURT HOUSE, OH—2026-07-09
HALLIDAY LUMBER, LLC
HENDERSON, TX—2026-06-30
W.D. TOWNLEY AND SON LUMBER COMPANY, INC.
BOYCEVILLE, WI—2026-06-26
SPECIALTY MANUFACTURING OF MENOMONIE, LLC
JACKSONVILLE, FL—2026-06-25
CHEP SERVICES, LLC
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.
SUNBURY, PA—2026-07-10
DEMPSEY UNIFORM & LINEN SUPPLY, INC
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
WILLIAMSPORT, PA—2026-07-10
INTERNATIONAL PAINT PROS
Source