OSHA Inspection: CHOMA CONSTRUCTION ENTERPRISES INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CHOMA CONSTRUCTION ENTERPRISES INC. in 295 NE 18TH STREET, MIAMI, FL 33132 (NAICS 238140). OSHA activity number 339543118.

Watch Choma Construction Enterprises INC. — free Get an email when a new federal OSHA severe-injury report for Choma Construction Enterprises INC. is published. One employer, no account, unsubscribe in one click.
Site address
295 NE 18TH STREET
City
MIAMI
State
FL
ZIP
33132
Mailing
5102 ISLAND CLUB DR, TAMARAC, FL 33319
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
3
Ownership type
A

4 citations on file for this inspection.

1926.451 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1600.00
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii):  On or about January 10, 2014, at the above addressed jobsite, an employee was working on a scaffold that was not fully planked.
Recent events (1)
  • — Z (S) $1600

1926.451 C02

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1600.00
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames,  or uprights did not bear on base plates, mud sills or other adequate firm foundation:  On or about January 10, 2014, at the above addressed jobsite, an employee was working on a scaffold in which the legs rested on a brick.
Recent events (1)
  • — Z (S) $1600

1926.451 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1600.00
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access:  On or about January 10, 2014, at the above addressed jobsite, an employee was working on a scaffold which did not have safe access to reach the platform.
Recent events (1)
  • — Z (S) $1600

1926.451 F07

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1600.00
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration.  Such activities were not performed only by experienced and trained employees selected for such work by the competent person:  On or about January 10, 2014, at the above addressed jobsite, the employer had erected a prefabricated frame scaffold without the supervision of a competent person.