EAST SYRACUSE, NY —
OSHA Inspection: WINROC-SPI
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of WINROC-SPI in 6741 OLD COLLAMER ROAD, EAST SYRACUSE, NY 13057 (NAICS 326140). OSHA activity number 339545303.
Where did this inspection happen?
- Establishment
- WINROC-SPI
- Site address
- 6741 OLD COLLAMER ROAD
- City
- EAST SYRACUSE
- State
- NY
- ZIP
- 13057
- Mailing
- 6741 OLD COLLAMER ROAD, EAST SYRACUSE, NY 13057
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326140
- Employees
- 20
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $3750.00 · Current $2250.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) In the Shop, on or about 1/14/14: Ingoing nip points at the pressure feed rollers for the Dunning & Boschert four post press #8 were not guarded. b) In the Shop, on or about 1/14/14: Ingoing nip points at the pressure feed rollers for the Dunning & Boschert four post press #7 were not guarded. c) Die Area, on or about 1/14/14: Rotating shaft and nut projection on a Central Machinery 8 inch bench grinder/buffer were not guarded at the wire brush attachment. d) In the Shop, on or about 1/14/14: Ingoing nip points at the feed roller for Laminator #10 were not adequately guarded. e) Pattern Cutting Area #2, on or about 1/14/14: Rotating chuck on a Dayton drill press was not guarded. Abatement certification must be submitted for these items.
Recent events (2)
- — I (S) $2250
- — Z (S) $3750
1910.305 G01 IV A
- Issued
- Abate by
- Penalty
- Initial $2250.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) In the Shop at rear door exit #2, on or about 1/14/14: An orange extension cord providing current to a leaf blower was tie wrapped along conduit and was being used as permanent wiring. b) In the Shop near two post press #1, on or about 1/14/14: Two orange extension cord providing current to portable equipment was attached to the wall surface, strung overhead and being used as permanent wiring. c) In the Shop by the mezzanine, on or about 1/14/14: A strip outlet with extension cords attached being used to power a bandsaw and other extension cords was stapled to the wall and being used as permanent wiring. Abatement certification must be submitted for these items.
Recent events (2)
- — I (O) $0
- — Z (S) $2250
1910.22 A01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition: a) In the shop by clicker #9, on or about 1/14/14: There was dust accumulation on the walls and along the electrical equipment behind clicker press #9. b) Pattern Cutting Area #1, on or about 1/14/14: There were extension cords piled on the floor in front of electrical equipment and a vertical bandsaw, creating a tripping hazard. Abatement certification must be submitted for these items.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at WINROC-SPI
DEWEY, AZ—2014-07-14 00:00:00
WINROC-SPI
View WINROC-SPI's full OSHA safety record →
More inspections in this industry (NAICS 326140)
BOLINGBROOK, IL—2026-06-09
CLARK FOAM PRODUCTS CORPORATION
SWEDESBORO, NJ—2026-04-30
DIVERSIFIED FOAM PRODUCTS
VISALIA, CA—2026-04-14
PREGIS INNOVATIVE PACKAGING LLC
CORONA, CA—2026-03-27
DART CONTAINER CORPORATION
EDISON, NJ—2026-03-26
CRYOPAK, INC.
More inspections in NY
MAYVILLE, NY—2026-07-16
MAYVILLE VILLAGE DPW
NEW HYDE PARK, NY—2026-07-16
NORTH HEMPSTEAD TN MICHAEL J TULLY PARK
CONESUS, NY—2026-07-16
CONESUS TN HIGHWAY DEPT
COMSTOCK, NY—2026-07-15
NYSDOCCS WASHINGTON CORRECTIONAL FACILITY
BALDWINSVILLE, NY—2026-07-15
LYSANDER TOWN HIGHWAY DEPARTMENT
Source