Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: WINROC-SPI

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WINROC-SPI in 6741 OLD COLLAMER ROAD, EAST SYRACUSE, NY 13057 (NAICS 326140). OSHA activity number 339545303.

Watch Winroc-Spi — free Get an email when a new federal OSHA severe-injury report for Winroc-Spi is published. One employer, no account, unsubscribe in one click.
Establishment
WINROC-SPI
Site address
6741 OLD COLLAMER ROAD
City
EAST SYRACUSE
State
NY
ZIP
13057
Mailing
6741 OLD COLLAMER ROAD, EAST SYRACUSE, NY 13057
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326140
Employees
20
Ownership type
A

3 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 5 instances 4 exposed
Issued
Abate by
Penalty
Initial $3750.00 · Current $2250.00 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    a)  In the Shop, on or about 1/14/14:  Ingoing nip points at the pressure feed rollers for the Dunning & Boschert four post press #8 were not guarded.    b) In the Shop, on or about 1/14/14: Ingoing nip points at the pressure feed rollers for the Dunning & Boschert four post press #7 were not guarded.    c)  Die Area, on or about 1/14/14:  Rotating shaft and nut projection on a Central Machinery 8 inch bench grinder/buffer were not guarded at the wire brush attachment.    d)  In the Shop, on or about 1/14/14:  Ingoing nip points at the feed roller for Laminator #10 were not adequately guarded.    e)  Pattern Cutting Area #2, on or about 1/14/14:  Rotating chuck on a Dayton drill press was not guarded.    Abatement certification must be submitted for these items.
Recent events (2)
  • — I (S) $2250
  • — Z (S) $3750

1910.305 G01 IV A

Other-than-serious 4 instances 3 exposed
Issued
Abate by
Penalty
Initial $2250.00 · Current $0.00 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:    a)  In the Shop at rear door exit #2, on or about 1/14/14:  An orange extension cord providing current to a leaf blower was tie wrapped along conduit and was being used as permanent wiring.    b)  In the Shop near two post press #1, on or about 1/14/14:  Two orange extension cord providing current to portable equipment was attached to the wall surface, strung overhead and being used as permanent wiring.    c)  In the Shop by the mezzanine, on or about 1/14/14:  A strip outlet with extension cords attached being used to power a bandsaw and other extension cords was stapled to the wall and being used as permanent wiring.      Abatement certification must be submitted for these items.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2250

1910.22 A01

Other-than-serious 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition:  a)  In the shop by clicker #9, on or about 1/14/14:  There was dust accumulation on the walls and along the electrical equipment behind clicker press #9.  b)  Pattern Cutting Area #1, on or about 1/14/14:  There were extension cords piled on the floor in front of electrical equipment and a vertical bandsaw, creating a tripping hazard.  Abatement certification must be submitted for these items.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View WINROC-SPI's full OSHA safety record →