OSHA Inspection: JENINGA BROS. METAL FORMING, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of JENINGA BROS. METAL FORMING, INC. in 1061 PROCTOR DRIVE, ELKHORN, WI 53121 (NAICS 332999). OSHA activity number 339547580.

Watch Jeninga Bros. Metal Forming, INC. — free Get an email when a new federal OSHA severe-injury report for Jeninga Bros. Metal Forming, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1061 PROCTOR DRIVE
City
ELKHORN
State
WI
ZIP
53121
Mailing
1061 PROCTOR DRIVE, ELKHORN, WI 53121
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
32
Ownership type
A

6 citations on file for this inspection.

1903.19 C01

Other-than-serious 1 instance 27 exposed
Issued
Abate by
Penalty
Initial $595.00 · Current $595.00
29 CFR 1903.19(c)(1): Within 10 calendar days after the abatement date, the employer must certify to OSHA (the Agency) that each cited violation has been abated, except as provided in paragraph (c)(2) of this section.  The employer failed to provide information certifying the provision of employee training on the new label elements and Safety Data Sheet (SDS) format.
Recent events (1)
  • — Z (O) $595

1910.217 C03 I E

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2975.00 · Current $1487.00 Reduced
29 CFR 1910.217(c)(3)(i)(e): Safety distance(s)(Ds) from the presence sensing field to the point of operation of mechanical power press(es) were not greater than the distance determined by the formula specified at 29 CFR 1910.217(c)(3)(iii)(e):          On or about January 21, 2014, the safety distance from the presence sensing field of the light curtain to the point of operation of the Minster 40-ton punch press (Press #15) was less than the distance determined by stop time measurements.
Recent events (2)
  • — I (S) $1487
  • — Z (S) $2975

1910.217 C03 VII D

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2975.00 · Current $1487.00 Reduced
29 CFR 1910.217(c)(3)(vii)(d): Two hand controls were not fixed in position so that only a supervisor or safety engineer was capable of relocating the controls:    On or about January 15, 2014, the two hand controls on the Niagara mechanical punch press (Press #21, Serial # 50499) were not fixed in position.
Recent events (2)
  • — I (S) $1487
  • — Z (S) $2975

1910.303 B07 IV

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2380.00 · Current $1190.00 Reduced
29 CFR 1910.303(b)(7)(iv): Damaged parts were present on electrical equipment that affected the safe operation or mechanical strength of the equipment:    On or about January 15, 2014, 110 volt control wiring conduit for the Niagara 400-ton punch press (Press #21, Serial # 50499) was damaged in such a way that the safe operation of the wiring was adversely impacted due to a broken section of flexible conduit that exposed the wiring.
Recent events (2)
  • — I (S) $1190
  • — Z (S) $2380

1910.303 G02 I

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2380.00 · Current $1190.00 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by use of approved cabinets or other forms of approved enclosures:    On or about January 15, 2014, the 110 volt toggle switch and associated wiring for the feed mechanism on the Niagara mechanical punch press (Press #21, Serial #50499) were not guarded against accidental contact by the use of approved cabinets or approved enclosures.
Recent events (2)
  • — I (S) $1190
  • — Z (S) $2380

1910.1200 H03 IV

Other-than-serious 27 instances 27 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(h)(3)(iv):  The employer had not provided employees with effective information and training on the details of the hazard communication program developed by the employer, including an explanation of the labels received on shipped containers and the workplace labeling system used by their employer; the safety data sheet, including the order of information and how employees can obtain and use the appropriate hazard information:  On or about January 15, 2014, the employer had not provided potentially exposed employees training on the new label elements and Safety Data Sheet (SDS) format.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339547580.