Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: WJM PARTNERS INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WJM PARTNERS INC. in 16732 INDUSTRIAL DRIVE RD, EAST BERNARD, TX 77435 (NAICS 332312). OSHA activity number 339550394.

Watch WJM Partners INC. — free Get an email when a new federal OSHA severe-injury report for WJM Partners INC. is published. One employer, no account, unsubscribe in one click.
Establishment
WJM PARTNERS INC.
Site address
16732 INDUSTRIAL DRIVE RD
City
EAST BERNARD
State
TX
ZIP
77435
Mailing
16732 INDUSTRIAL DRIVE RD, EAST BERNARD, TX 77435
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
10
Ownership type
A

4 citations on file for this inspection.

1910.157 E01

Serious Gravity 1 4 instances 8 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $720.00 Reduced
29 CFR 1910.157(e)(1): The employer did not inspect, maintain and test portable fire extinguishers in the workplace:  At this worksite, there were fire extinguishers in the shop at several locations that had not been inspected for over a year.
Recent events (2)
  • — I (S) $720
  • — Z (S) $1200

1910.184 D

Serious Gravity 5 2 instances 8 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1200.00 Reduced
29 CFR 1910.184(d): Sling(s) and fastenings were not inspected each day or during use and were not removed from service when damaged or defective:  At this worksite, on the inside mid-north side of the shop, employees were exposed to a struck by or caught in hazard due to transporting heavy objects with a damaged web sling.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1910.305 B01 II

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1200.00 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  At this fab metal shop site, there was a conductor/breaker box located in the middle of the shop area, with an opening from a knock-out hole underneath.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1910.145 C03

Other-than-serious 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $400.00 · Current $240.00 Reduced
29 CFR 1910.145(c)(3): Safety instruction sign(s) were not used where there was a need for general instructions and suggestions relative to safety measure(s):  At this worksite on the north side outer building area, an aluminum shack that stores both oxygen and acetylene tanks did not bear any signs to give warning of the stored products.
Recent events (2)
  • — I (O) $240
  • — Z (O) $400