SAINT FRANCIS, WI —
OSHA Inspection: FONTAROME CHEMICAL, INC.
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of FONTAROME CHEMICAL, INC. in 4170 S. NEVADA AVENUE, SAINT FRANCIS, WI 53235 (NAICS 325998). OSHA activity number 339558595.
Where did this inspection happen?
- Establishment
- FONTAROME CHEMICAL, INC.
- Site address
- 4170 S. NEVADA AVENUE
- City
- SAINT FRANCIS
- State
- WI
- ZIP
- 53235
- Mailing
- 1135 S. MAIN STREET, RACINE, WI 53403
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325998
- Employees
- 27
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.134 D01 III
- Issued
- Abate by
- Penalty
- Initial $5390.00 · Current $5390.00
General-duty citation text
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminants chemical state and physical form. When the employer was unable to identify or reasonably estimate the employee exposure, the employer did not consider the atmosphere to be IDLH: a) The employer had not performed an evaluation or identification of respiratory hazards for chemical hazards such as, but not limited to thionyl chloride and nonivamide. b) On or about February 11th, 2014 employees were exposed to elevated levels of carbon dioxide from dry ice in the cold storage room. No evaluation for employee exposure was performed.
Recent events (1)
- — Z (S) $5390
1910.134 H02 I
- Issued
- Abate by
- Penalty
- Initial $3080.00 · Current $3080.00
General-duty citation text
29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or were not packed or stored to prevent deformation of the facepiece and exhalation valve: a) On or about February 12, 2014 an employee was observed storing a tight fitting half face air purifying respirator with the face seal facing up on the work platform decking of filter dryer FD-301.
Recent events (1)
- — Z (S) $3080
1910.134 K01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(k)(1): The employer did not provide respirator training that would ensure each employee could demonstrate knowledge of items in section (i)-(vii): a) The employer had not provided information and training on proper use and care of respirators where production employees are required to wear full and half mask negative pressure respirators when working with chemicals such as, but not limited to, thionyl chloride and nonivamide.
Recent events (1)
- — Z (S) $0
1910.134 F01
- Issued
- Abate by
- Penalty
- Initial $10780.00 · Current $10780.00
General-duty citation text
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): (a) On or about December 16, 2013 the employer had not performed annual fit testing for employees required to wear full and half mask negative pressure respirators prior to working with chemicals such as, but not limited to, thionyl chloride and nonivamide. Fontarome Chemical, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.134(f)(1) which was contained in OSHA inspection number 480099, citation number 1, item number 2, issued on October 30, 2012, which was affirmed as a final order on November 7, 2012 with respect to a workplace located at 4170 S. Nevada Avenue Milwaukee, Wisconsin 53225.
Recent events (1)
- — Z (R) $10780
More inspections at FONTAROME CHEMICAL, INC.
SAINT FRANCIS, WI—2013-12-16 00:00:00
FONTAROME CHEMICAL, INC.
SAINT FRANCIS, WI—2013-05-15 00:00:00
FONTAROME CHEMICAL, INC.
MILWAUKEE, WI—2012-06-22 00:00:00
FONTAROME CHEMICAL, INC.
SAINT FRANCIS, WI—2012-04-13 00:00:00
FONTAROME CHEMICAL, INC.
View FONTAROME CHEMICAL, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 325998)
CHARLOTTE, TX—2026-07-07
CLEMENTS FLUIDS
KINDRED, ND—2026-06-29
ICE CRYSTAL ENGINEERING
WAYNESVILLE, NC—2026-06-23
161409 - PREMIER MAGNESIA, LLC
SOUTH PLAINFIELD, NJ—2026-06-17
AVINTHIA INC
WARMINSTER, PA—2026-06-12
CRC INDUSTRIES, INCORPORATED
More inspections in WI
MUSCODA, WI—2026-07-10
SCOT INDUSTRIES, INC
FRANKLIN, WI—2026-07-10
EDGE BROADBAND SOLUTIONS LLC
APPLETON, WI—2026-07-10
LAWRENCE UNIVERSITY OF WISCONSIN
KIMBERLY, WI—2026-07-10
ENRIQUE RESENDIC
SLINGER, WI—2026-07-10
DYLAN MATTHEW SHELLEY LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339558595.