Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: FOSTER BROTHERS WOOD PRODUCTS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FOSTER BROTHERS WOOD PRODUCTS in 6465 HWY E, AUXVASSE, MO 65231 (NAICS 321999). OSHA activity number 339561300.

Watch Foster Brothers Wood Products — free Get an email when a new federal OSHA severe-injury report for Foster Brothers Wood Products is published. One employer, no account, unsubscribe in one click.
Site address
6465 HWY E
City
AUXVASSE
State
MO
ZIP
65231
Mailing
P.O. BOX 232, AUXVASSE, MO 65231
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321999
Employees
48
Ownership type
A

4 citations on file for this inspection.

1910.304 G05

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2625.00 · Current $1838.00 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:  a. A shop light was used with a missing ground pin on the power cord.  Abatement documentation is required for this violation.
Recent events (2)
  • — I (S) $1837.5
  • — Z (S) $2625

1910.305 B01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  a. In the shop, an extension cord was made with an outlet box; the box had a "knockout" missing from the side of the box (note: an outlet box designed for mounting is not listed for use as an extension cord).  Abatement documentation is required for this violation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:  a. In the shop, 110 V receptacles were used with damaged or loose covers.  Abatement documentation is required for this violation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.334 A02 II

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service:  a. The fabricated extension cord (with an outlet box as the receptacle) was used with a cover on the plug end, that was not in place (loose, potentially exposing terminal connections to the plug blades).  (Note: there is no longer any approval for plugs with this type of cover, but must be of a solid construction.)  Abatement documentation is required for this violation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0