Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: EAGAN MANUFACTURING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of EAGAN MANUFACTURING, INC. in 602 EAGAN RD, BLACK ROCK, AR 72415 (NAICS 332321). OSHA activity number 339561839.

Watch Eagan Manufacturing, INC. — free Get an email when a new federal OSHA severe-injury report for Eagan Manufacturing, INC. is published. One employer, no account, unsubscribe in one click.
Site address
602 EAGAN RD
City
BLACK ROCK
State
AR
ZIP
72415
Mailing
602 EAGAN RD, BLACK ROCK, AR 72415
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332321
Employees
45
Ownership type
A

4 citations on file for this inspection.

1910.212 A01

Serious Gravity 10 5 instances 8 exposed
Issued
Abate by
Penalty
Initial $4900.00 · Current $4900.00
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:   On or about January 23, 2014, at Eagan Manufacturing in Black Rock, Arkansas, employees involved in manufacturing window and door assemblies were exposed to struck by or caught-in hazards in the following instances:  a) The metal shear, used for door panels, labeled #39, located in the door shop, had an unguarded opening greater than 1/4 of an inch.  b) The Ryobi drill press, in the northwest corner of the door shop, used to assemble attic inlets, was not equipped with a chuck guard.  c) The drill press nearest the north wall, in the northeast corner of the window shop, used to assemble door frames, was not equipped with a chuck guard.  d) The second drill press from the north wall, in the northeast corner of the window shop, used to assemble window frames, was not equipped with a chuck guard.  e) The third drill press from the north wall, in the northeast corner of the window shop, used to assemble window frames, was not equipped with a chuck guard.
Recent events (1)
  • — Z (S) $4900

1910.215 B09

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1785.00 · Current $1785.00
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  On or about January 23, 2014, in the outside door area of the Eagan Manufacturing facility in Black Rock, Arkansas, where employees were required to operate a bench grinder, the grinder did not have an adjustable tongue guard and the distance from the top of the fixed safety guard to the abrasive wheel exceeded 1/4 of an inch. This created conditions which exposed the employee to the hazard of being struck by flying abrasive wheel particles.
Recent events (1)
  • — Z (S) $1785

1910.147 C06 I

Other-than-serious 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:    On or about January 23, 2014, at the Eagan Manufacturing facility in Black Rock, Arkansas, employees were performing maintenance and set ups on equipment such as but not limited to punch presses and shears, under lock out applications. The employer had performed a periodic review of the written procedures but the review had not included observation of the actual lock out applications to ensure the procedures were being followed.
Recent events (1)
  • — Z (O) $0

1910.303 E01 II

Other-than-serious 2 instances 20 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(e)(1)(ii): Electrical equipment was used when the markings giving voltage, current, wattage, or other ratings as necessary were missing.  Instance a) On or about January 23, 2014, in the door shop, of the Eagan Manufacturing facility, in Black Rock, Arkansas, where employees were manufacturing metal doors and frames, the breaker panel near the center door at the front of the building was not labeled with voltage, wattage, current, or other ratings.   Instance b) On or about January 23, 2014, in the window shop, of the Eagan Manufacturing facility, in Black Rock, Arkansas, where employees were manufacturing metal windows and frames, the breaker panels near the northeast corner of the building was not labeled with voltage, wattage, current, or other ratings.
Recent events (1)
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339561839.