Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: WIZARD SERVICES USA LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WIZARD SERVICES USA LLC in 4406 NE 6TH AVE, OAKLAND PARK, FL 33334 (NAICS 561730). OSHA activity number 339562373.

Watch Wizard Services USA LLC — free Get an email when a new federal OSHA severe-injury report for Wizard Services USA LLC is published. One employer, no account, unsubscribe in one click.
Site address
4406 NE 6TH AVE
City
OAKLAND PARK
State
FL
ZIP
33334
Mailing
4406 NE 6TH AVE, OAKLAND PARK, FL 33334
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561730
Employees
20
Ownership type
A

12 citations on file for this inspection.

1910.36 D02

Serious Gravity 10 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1680.00 Reduced
29 CFR 1910.36(d)(2): Exit route doors must be free of any device or alarm that could restrict emergency use of the exit route if the device or alarm fails.  a. On or about January 24, 2014, at the above addressed job site, employees were exposed to the hazard of smoke inhalation / asphyxiation, while working in a building that had the rear exit door secured from the outside with a metal bar that had been welded in place.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.36 G04

Serious Gravity 10 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1680.00 Reduced
29 CFR 1910.36(g)(4): Objects that project into the exit route must not reduce the width of the exit route to less than the minimum width requirements for exit routes.   a. On or about January 24, 2014, at the above addressed job site, employees were exposed to the hazards of falling and smoke inhalation / asphyxiation, while working in a building that had the exit routes blocked.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.37 A03

Serious Gravity 5 2 instances 6 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed:   a. On or about January 24, 2014, at the above addressed job site, employees were exposed to the hazards of smoke inhalation / asphyxiation, while working in a building that had the exit routes obstructed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.141 A03 I

Serious Gravity 5 1 instance 20 exposed
Issued
Abate by
Penalty
Initial $2400.00 · Current $1440.00 Reduced
29 CFR 1910.141(a)(3)(i): Places of employment were not kept clean to the extent that the nature of the work allowed   a. On or about January 24, 2014, at the above addressed job site, employees were exposed to the hazard of struck by, while working in a warehouse that had loose tools and other equipment sitting on a work bench that could accidentally be knocked off.
Recent events (2)
  • — I (S) $1440
  • — Z (S) $2400

1910.141 B01 I

Serious Gravity 10 3 instances 18 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1680.00 Reduced
29 CFR 1910.141(b)(1)(i): Potable water was not provided in all places of employment, for drinking, washing of the person, cooking, washing of foods, washing of cooking or eating utensils, washing of food preparation or processing premises, and personal.    a. On or about January 24, 2014, at the above addressed job site, employees were exposed to heat related illnesses and unsanitary health conditions, while conducting landscaping operations without potable water.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.215 A03

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1680.00 Reduced
29 CFR 1910.215(a)(3): Grinding machine(s) were not equipped with flanges in accordance with 29 CFR 1910.215(c):   a. On or about January 24, 2014, at the above addressed job site, an employee was exposed to the hazard of struck-by tools and / or components of a bench grinder, while using a bench grinder that did not have the safety flange installed.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.215 A04

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:   a. On or about January 24, 2014, at the above addressed job site, an employee was exposed to the hazard of struck-by, while using a bench grinder that did not have the work rest adjusted correctly.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.215 B09

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:   a. On or about January 24, 2014, at the above addressed job site, an employee was exposed to the hazard of being struck-by tools and / or flying projectiles of an abrasive wheel, while using a bench grinder that was missing the tongue guard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:   a. On or about January 24, 2014, at the above addressed job site, an employee was exposed to the hazard of being struck-by tools and / or flying projectiles of an abrasive wheel, while using a bench grinder that hardwired to bypass the on-off switch.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G02 I

Serious Gravity 10 1 instance 20 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1680.00 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):   a. On or about January 24, 2014, at the above addressed job site, employees were exposed to the hazard of electrical shock, while using an electrical switch to operate a garage door that was missing the wall plate cover.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.304 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1200.00 Reduced
29 CFR 1910.304(b)(1): Identification of multiwire branch circuits. Where more than one nominal voltage system exists in a building containing multiwire branch circuits, each ungrounded conductor of a multiwire branch circuit, where accessible, shall be identified by phase and system. The means of identification shall be permanently posted at each branch-circuit panelboard:   a. On or about January 24, 2014, at the above addressed job site, an employee was exposed to the hazard of electrical shock, while using a breaker panel that did not have the breakers labeled correctly in a breaker panel box with missing knock-out covers.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1910.305 B01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:   a. On or about January 24, 2014, at the above addressed job site, an employee was exposed to the hazard of electrical shock, while using circuit breakers in a breaker panel that had missing knock-out covers.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339562373.