LE ROY, NY —
OSHA Inspection: PCORE ELECTRIC, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PCORE ELECTRIC, INC. in 135 GILBERT STREET, LE ROY, NY 14482 (NAICS 335999). OSHA activity number 339566929.
Where did this inspection happen?
- Establishment
- PCORE ELECTRIC, INC.
- Site address
- 135 GILBERT STREET
- City
- LE ROY
- State
- NY
- ZIP
- 14482
- Mailing
- 135 GILBERT STREET, LE ROY, NY 14482
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 335999
- Employees
- 68
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.23 C01
- Issued
- Abate by
- Penalty
- Initial $2975.00 · Current $1488.00 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floor(s) or platform(s) 4 feet (1.22 m) or more above the adjacent floor or ground level were not guarded by standard railings (or the equivalent as specified in 29 CFR 1910.23(e)(3)(i) through (v)), on all open sides: a) On or about 01/31/2014 in the resin department; where the guardrail on the operators' platform, approximately 10 feet above the floor below, was only 36 inches high. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $1487.5
- — Z (S) $2975
1910.146 J04
- Issued
- Abate by
- Penalty
- Initial $2975.00 · Current $1488.00 Reduced
General-duty citation text
29 CFR 1910.146(j)(4): The employer did not ensure that each entry supervisor verified that rescue services were available and that the means for summoning them were operable: a) On or about 01/31/2014 in the production areas; for regular entries into permit required confined spaces (PRCS), where the employer depends on "911 emergency responders", the employer did not notify the "911 emergency responders" prior to the PRCS entries. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $1487.5
- — Z (S) $2975
1910.303 H05 I
- Issued
- Abate by
- Penalty
- Initial $2975.00 · Current $1488.00 Reduced
General-duty citation text
29 CFR 1910.303(h)(5)(i): Except as elsewhere required or permitted in this subpart, the minimum clear working space in the direction of access to live parts of electric equipment may not be less than specified in Table S-2: a) On or about 01/31/2014 at the PRC test station; where test voltages up to 10KV are applied to bushings on a roller conveyor immediately adjacent to the main aisle in the area. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $1487.5
- — Z (S) $2975
1910.333 B02 III A
- Issued
- Abate by
- Penalty
- Initial $2975.00 · Current $1488.00 Reduced
General-duty citation text
29 CFR 1910.333(b)(2)(iii)(A): A lock and a tag were not placed on each disconnecting means used to deenergize circuits and equipment on which work was to be performed: a) On or about 01/31/2014 in the high voltage test lab; where servicing and/or maintenance such as, but not limited to adjusting the generator and capacitors was performed without locking out the electrical energy. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $1487.5
- — Z (S) $2975
1910.37 B05
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g. closet): a) On or about 01/31/2014 in the 2nd floor foil cutting area: where a door to upstairs office space could be confused as an exit door. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.147 C05 II
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(5)(ii): Lockout devices and tagout devices were utilized for purposes other than controlling energy: a) On or about 01/31/2014 in the winding room; where a "lockout lock" was used to lock a door closed. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.147 C06 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed: a) On or about 01/31/2014 throughout establishment; where the employer did not certify the periodic (at least annual) review of all of the energy control procedures. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.253 B04 III
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least 1 hour: a) On or about 01/31/2014 in the main manufacturing area; where oxygen cylinders ("empty" and full) were stored next to "empty" acetylene cylinders in a compressed gas cylinder cage. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 G01 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: a) On or about 01/31/2014 in the parts stock room; where the space in front of a control panel was used for storage of palletized parts and material. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 335999)
ANDOVER, MA—2026-07-09
VICOR CORPORATION
WILLIAMSBURG, VA—2026-07-07
EATON CORPORATION
FRANKFORT, IL—2026-07-06
QUANTUM TECHNICAL SERVICES INC.
WILLIAMSBURG, VA—2026-06-23
EATON CORPORATION
HUMACAO, PR—2026-06-17
EEMCO LLC
More inspections in NY
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
HEMPSTEAD, NY—2026-07-13
NYSDOCCS NASSAU AREA OFFICE
NIAGARA FALLS, NY—2026-07-10
NTVI FEDERAL INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339566929.