Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: ECOLAB, INC. DBA PUREFORCE

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ECOLAB, INC. DBA PUREFORCE in 942 BAKER ROAD, MARTINSBURG, WV 25405 (NAICS 325611). OSHA activity number 339571614.

Watch Ecolab, INC. DBA Pureforce — free Get an email when a new federal OSHA severe-injury report for Ecolab, INC. DBA Pureforce is published. One employer, no account, unsubscribe in one click.
Site address
942 BAKER ROAD
City
MARTINSBURG
State
WV
ZIP
25405
Mailing
942 BAKER ROAD, MARTINSBURG, WV 25405
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325611
Employees
161
Ownership type
A

2 citations on file for this inspection.

1910.106 B06

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $4000.00 · Current $3000.00 Reduced
29 CFR 1910.106(b)(6): In locations where flammable vapors may be present, precautions were not taken to prevent ignition by eliminating or controlling sources of ignition.  Sources of ignition may include open flames, lightning, smoking, hot surfaces, frictional heat, sparks (static, electrical, and mechanical), spontaneous ignition, chemical and physical-chemical reactions, and radiant heat:   (a)  Glacial Acetic Acid Tank:  A portable kerosene heater was used inside of a dike with a storage tank containing 100 percent Glacial Acetic Acid, which is a Category 3 flammable liquid, for the purpose of heating the acid during excessive cold weather while it was pumped through a filter unit that was inside of the dike as determined on February 3, 2014.   ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $3000
  • — Z (S) $4000

1910.1200 F05

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(f)(5): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged, or marked with the identity and appropriate hazard warnings regarding the chemicals contained therein:  (a)  Glacial Acetic Acid Tank:  The employer was using the NFPA format for labeling the hazards of the storage tank of glacial acetic acid and the triangle for the fire rating was not painted red as determined on February 3, 2014.  ABATEMENT CERTIFICATION REQUIRED.