CHEEKTOWAGA, NY —
OSHA Inspection: EXPERT DRYWALL CONSTRUCTION, INC
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of EXPERT DRYWALL CONSTRUCTION, INC in 4989 GENESEE STREET, CHEEKTOWAGA, NY 14225 (NAICS 238310). OSHA activity number 339574311.
Where did this inspection happen?
- Establishment
- EXPERT DRYWALL CONSTRUCTION, INC
- Site address
- 4989 GENESEE STREET
- City
- CHEEKTOWAGA
- State
- NY
- ZIP
- 14225
- Mailing
- 298 ENSMINGER ROAD, TONAWANDA, NY 14150
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238310
- Employees
- 6
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.404 B01 II
- Issued
- Penalty
- Initial $1200.00 · Current $720.00 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection: a) On or about 2/4/14, at apartment 100 area of the site, Cheektowaga, NY. Ground fault circuit interrupters were not used, where tools drew power through flexible cord sets. Employees were exposed to shock. No Abatement Certification Required
Recent events (2)
- — I (S) $720
- — Z (S) $1200
1926.405 A02 II J
- Issued
- Penalty
- Initial $1200.00 · Current $720.00 Reduced
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(J): Extension cord sets used with portable electric tools and appliances were not designed for hard or extra-hard usage: a) On or about 2/4/14, at apartment 100 area of the site, Cheektowaga, NY. Extension cord sets used for power tools were not designed for hard or extra-hard usage. No Abatement Certification Required
Recent events (2)
- — I (S) $720
- — Z (S) $1200
1926.1052 C01 I
- Issued
- Penalty
- Initial $1200.00 · Current $720.00 Reduced
General-duty citation text
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail: a) On or about 2/4/14, at apartment 100 area of the site, Cheektowaga, NY. Stairways of 18 step risers were not equipped with at least one handrail. No Abatement Certification Required
Recent events (2)
- — I (S) $720
- — Z (S) $1200
More inspections in this industry (NAICS 238310)
ELLETTSVILLE, IN—2026-07-13
ENVIRO HEAT, LLC
ELLETTSVILLE, IN—2026-07-13
RWS INSULATION SERVICES, LLC
IRVINE, CA—2026-07-10
COAST BUILDING PRODUCTS
FRANCESTOWN, NH—2026-07-10
D&D INSULATION, LLC
DOWNINGTOWN, PA—2026-07-09
CAPITAL INTERIOR, LLC
More inspections in NY
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
HEMPSTEAD, NY—2026-07-13
NYSDOCCS NASSAU AREA OFFICE
NIAGARA FALLS, NY—2026-07-10
NTVI FEDERAL INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339574311.