OSHA Inspection: SQUIRES METAL FABRICATION INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SQUIRES METAL FABRICATION INC. in 2511 E. ERWIN, TYLER, TX 75702 (NAICS 331221). OSHA activity number 339574634.

Watch Squires Metal Fabrication INC. — free Get an email when a new federal OSHA severe-injury report for Squires Metal Fabrication INC. is published. One employer, no account, unsubscribe in one click.
Site address
2511 E. ERWIN
City
TYLER
State
TX
ZIP
75702
Mailing
2511 E. ERWIN, TYLER, TX 75702
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331221
Employees
6
Ownership type
A

2 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1400.00 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish to each of his employees employment and a place of employment which were free from recognized hazards created by contact with the point of operation that were causing or were likely to cause death or serious physical harm to his employees:    This violation was observed on or about February 5, 2015; where the unguarded foot-operated control to the CMF hydraulic press brake exposed employees to hazards causing or likely to cause amputations and/or broken bones.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.147 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1000.00 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative.    This violation occurred on or about February 5, 2014, when the employer did not establish a program consisting of energy control procedures including but not limited to employee training and periodic inspections.