Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: FOUSTINO GALVAN

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FOUSTINO GALVAN in 320 ADVERSTONE COURT, FAYETTEVILLE, GA 30214 (NAICS 238130). OSHA activity number 339576696.

Watch Foustino Galvan — free Get an email when a new federal OSHA severe-injury report for Foustino Galvan is published. One employer, no account, unsubscribe in one click.
Establishment
FOUSTINO GALVAN
Site address
320 ADVERSTONE COURT
City
FAYETTEVILLE
State
GA
ZIP
30214
Mailing
3439 HARRIS FARMS WAY, AUSTELL, GA 30106
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
4
Ownership type
A

2 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 2 instances 2 exposed
Issued
Penalty
Initial $2800.00 · Current $1680.00 Reduced
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m)  or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502:     (a) Second floor, new residential construction located at 320 Adverstone Court, Fayetteville, GA 30214: Employee was exposed to falls while engaged in framing activities at heights of approximately 10-feet, 11-inches from the lower level with no fall protection system in place.    (b) Rear top plate, new residential construction located at 320 Adverstone Court, Fayetteville, GA 30214: Employee was exposed to falls while framing ceiling joist from the top plate located at heights of approximately 18-feet, 11-inches from the lower level without a fall protection system in place.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1926.1052 C01 II

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2000.00 · Current $1200.00 Reduced
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge:    (a) Stairway, new residential construction located at 320 Adverstone Court, Fayetteville, GA 30214: Employees were exposed to falls while using a stairway to access the second level which was not provided with stair rails along the open side which was 6 risers high approximately 44-1/2-inches from the concrete surface below.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

View FOUSTINO GALVAN's full OSHA safety record →