PASCOAG, RI —
OSHA Inspection: LOCKHEED WINDOW CORP.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of LOCKHEED WINDOW CORP. in ROUTE 100, PASCOAG, RI 02859 (NAICS 332321). OSHA activity number 339577454.
Where did this inspection happen?
- Establishment
- LOCKHEED WINDOW CORP.
- Site address
- ROUTE 100
- City
- PASCOAG
- State
- RI
- ZIP
- 02859
- Mailing
- P.O. BOX 166, PASCOAG, RI 02859
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332321
- Employees
- 90
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.22 D01
- Issued
- Abate by
- Penalty
- Initial $1575.00 · Current $1050.00 Reduced
General-duty citation text
29 CFR 1910.22(d)(1): In every building or other structure, or part thereof, used for mercantile, business, industrial, or storage purposes, the loads approved by the building official were not marked on plates of approved design which were supplied and securely affixed by the owner of the building, or the duly authorized agent, in a conspicuous place in each space to which they related: a) Commercial Window Department: The approved floor load capacity was not posted for the elevated storage area. b) Frame Department: The approved floor load capacity was not posted for the elevated office area.
Recent events (2)
- — I (S) $1050
- — Z (S) $1575
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $3150.00 · Current $3150.00
General-duty citation text
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s)created by rotating parts and in running nip points: (a) Tool Room: The unused portion of the sanding belt, on the vertical belt sander, was not provided with a guard to prevent accidental contact.
Recent events (2)
- — I (S) $3150
- — Z (S) $3150
1910.219 C04 I
- Issued
- Abate by
- Penalty
- Initial $3150.00 · Current $3150.00
General-duty citation text
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and projected more than one half the diameter of the shaft: (a) Tool Room: The rotating shaft end, on the Vertical Sander, projected more then one half the diameter of the shaft and was not guarded by a non rotating cap or safety sleeve.
Recent events (2)
- — I (S) $3150
- — Z (S) $3150
1910.333 B02 I
- Issued
- Abate by
- Penalty
- Initial $2625.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.333(b)(2)(i): The employer did not maintain a written copy of the procedures outlined in paragraph (b)(2) of 29 CFR 1910.333 and did not make it available for inspection by the Assistant Secretary of Labor and his or her authorized representatives: a) Establishment: The employer did not have or maintain a written copy of their procedures for Electrical Safety- Related Work Practices as outlined in paragraph (b)(2) of 29 CFR 1910.333.
Recent events (2)
- — I (S) $0
- — Z (S) $2625
1910.335 A01 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not provided with electrical protective equipment that was appropriate for the specific parts of the body that needed to be protected and for the work being performed: a) Throughout the Establishment: The employee performing testing for de-energization was not provided with adequate electrical protective equipment, such as but not limited to, Type O gloves, rubber insulated gloves, electric rated face shield, electric rated hard hat, protective clothing and insulated mats.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at LOCKHEED WINDOW CORP.
SOUTH EASTON, MA—2012-10-03 00:00:00
LOCKHEED WINDOW CORP
SOUTH EASTON, MA—2012-10-02 00:00:00
LOCKHEED WINDOW CORP
View LOCKHEED WINDOW CORP.'s full OSHA safety record →
More inspections in this industry (NAICS 332321)
WAITE PARK, MN—2026-06-12
111407 - HEARTLAND GLASS CO INC
TEMECULA, CA—2026-06-11
MILGARD MANUFACTURING LLC
NEWTON, NC—2026-06-04
161329 - AADG, INC.
BALDWIN PARK, CA—2026-05-26
LAWRENCE ROLL UP DOORS, INC.
BENTON HARBOR, MI—2026-05-14
R BETKER & ASSOCIATES INC.
More inspections in RI
NEWPORT, RI—2026-07-10