Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SHANER INVESTMENTS WHITE OAKS, L.P.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SHANER INVESTMENTS WHITE OAKS, L.P. in 30 SHANER DRIVE, BRIDGEPORT, WV 26330 (NAICS 721110). OSHA activity number 339579757.

Watch Shaner Investments White Oaks, L.P. — free Get an email when a new federal OSHA severe-injury report for Shaner Investments White Oaks, L.P. is published. One employer, no account, unsubscribe in one click.
Site address
30 SHANER DRIVE
City
BRIDGEPORT
State
WV
ZIP
26330
Mailing
1 PPG PLACE SUITE 2370, PITTSBURGH, PA 15222
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
721110
Employees
5
Ownership type
A

3 citations on file for this inspection.

1926.153 H11

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1800.00 · Current $1800.00
29 CFR 1926.153(h)(11): Containers having a water capacity greater than 2.5 pounds (nominal 1 pound LP-Gas capacity) connected for use did not stand on a firm and substantial surface and, when necessary, were not secured in an upright position:    (a) Hotel Front Entrance: Employees were using two LP-Gas containers to power two 375,000 Max BTU Torpedo Heaters, no s/n. The LP-Gas Containers were located unsecured on an uneven surface inside the building and not secured, as observed on or about 02/07/2014.   ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
  • — Z (S) $1800

1926.153 H13

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.153(h)(13): For temporary heating, heaters (other than integral heater-container units) were not located at least 6 feet from any LP-Gas container, blower and radiant type heaters shall not be directed toward any LP-Gas container within 20 feet:  (a) Hotel Front Entrance: Employees were using two LP-Gas containers to power two 375,000 Max BTU Torpedo Heaters, no s/n. The LP-Gas Containers were located between 30-46 inches from the heaters and one heater was found blowing toward an LP-Gas container located 46 inches away, as observed on or about 02/07/2014.  ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
  • — Z (S) $0

1910.1200 H03 IV

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(h)(3)(iv):   The details of the hazard communication program developed by the employer, did not include an explanation of the labels received on shipped containers and the workplace labeling system used by their employer; the safety data sheet, including the order of information and how employee could obtain and use the appropriate hazard information: (Construction Reference: 1926.59)    (a) Shaner Investments White Oaks, L.P.: The employees were not provided training on the new SDS (safety data sheets) and label formats on materials used as determined on or about 02/07/2014.  ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339579757.