Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: ALPHA GROUP CONSTRUCTION, INC.

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of ALPHA GROUP CONSTRUCTION, INC. in 30 SHANER DRIVE, BRIDGEPORT, WV 26330 (NAICS 238310). OSHA activity number 339579898.

Watch Alpha Group Construction, INC. — free Get an email when a new federal OSHA severe-injury report for Alpha Group Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
30 SHANER DRIVE
City
BRIDGEPORT
State
WV
ZIP
26330
Mailing
P.O. BOX 6211, KNOXVILLE, TN 37914
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238310
Employees
25
Ownership type
A

3 citations on file for this inspection.

1926.153 H11

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1800.00 · Current $1080.00 Reduced
29 CFR 1926.153(h)(11): Containers having a water capacity greater than 2 1/2 pounds (nominal 1 pound LP-Gas capacity) connected for use did not stand on a firm and substantial surface and, when necessary, were not secured in an upright position:    (a) Hotel Front Entrance: Employees were using an LP-Gas container to power a 375,000 Max BTU Torpedo Heater, no s/n. The LP-Gas Container was located unsecured on an uneven surface inside the building and not protected, as observed on or about 02/07/2014.     ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $1080
  • — Z (S) $1800

1926.153 H13

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.153(h)(13): For temporary heating, heaters (other than integral heater-container units) were not located at least 6 feet from any LP-Gas container, blower and radiant type heaters shall not be directed toward any LP-Gas container within 20 feet:  (a) Hotel Front Entrance: Employees were using an LP-Gas container to power a 375,000 Max BTU Torpedo Heater, no s/n. The LP-Gas container was located 46 inches away from the blower and in front of the blower, as observed on or about 02/07/2014.   ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 H03 IV

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(h)(3)(iv):   The details of the hazard communication program developed by the employer, did not include an explanation of the labels received on shipped containers and the workplace labeling system used by their employer; the safety data sheet, including the order of information and how employee could obtain and use the appropriate hazard information: (Construction Reference: 1926.59)   (a) Alpha Group Construction, Inc.: The employees were not provided training on the new SDS (safety data sheets) and label formats on materials used as determined on or about 02/07/2014.  ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339579898.