WESTERN SPRINGS, IL —
OSHA Inspection: PK WOODWORK CONSTRUCTION, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PK WOODWORK CONSTRUCTION, INC. in 4228 ROSE AVE., WESTERN SPRINGS, IL 60558 (NAICS 238350). OSHA activity number 339583163.
Where did this inspection happen?
- Establishment
- PK WOODWORK CONSTRUCTION, INC.
- Site address
- 4228 ROSE AVE.
- City
- WESTERN SPRINGS
- State
- IL
- ZIP
- 60558
- Mailing
- 518 MAPLE LN, DARIEN, IL 60561
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238350
- Employees
- 2
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.300 B01
- Issued
- Penalty
- Initial $2800.00 · Current $980.00 Reduced
General-duty citation text
29 CFR 1926.300(b)(1): When power operated tools are designed to accommodate guards, they shall be equipped with such guards when in use. a. On or about February 12, 2014, at the above addressed jobsite, a table saw was observed to be missing the blade guard, thereby exposing the employee to an amputation hazard.
Recent events (2)
- — I (S) $980
- — Z (S) $2800
1926.416 E01
- Issued
- Abate by
- Penalty
- Initial $2400.00 · Current $840.00 Reduced
General-duty citation text
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables shall not be used. a. On or about February 12, 2014 - at the above addressed jobsite, a frayed electric cord was used to power electrical tools such as a table saw, thereby exposing the employees to hazards associated with electrical shock.
Recent events (2)
- — I (S) $840
- — Z (S) $2400
1926.451 B05 II
- Issued
- Penalty
- Initial $2800.00 · Current $980.00 Reduced
General-duty citation text
29 CFR 1926.451(b)(5)(ii): Each platform greater than 10 feet in length shall not extend over its support more than 18 inches (46 cm), unless it is designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end. a. On or about February 12, 2014 - at the above addressed jobsite, an employee was performing siding installation from a pump jack scaffold that had a platform extending greater than eighteen (>18") inches past its supports, thereby exposing the employee to a fall of approximately twenty one (21) feet to the ground.
Recent events (2)
- — I (S) $980
- — Z (S) $2800
1926.451 F15
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(f)(15): Ladders shall not be used on scaffolds to increase the working level height of employees, except on large area scaffolds where employers have satisfied the following criteria: a. On or about February 12, 2014 - at the above addressed jobsite, an employee performing siding installation from a pump jack scaffold, approximately twenty one (21) feet above the ground, was using a 6' ladder to increase the working level height, thereby exposing the employee to a fall hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 G04 I
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(g)(4)(i): Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews. a. On or about February 12, 2013 - at the above addressed jobsite, an employee performing siding installation from a pump jack scaffold, approximately twenty one (21) feet above the ground, was exposed to injuries from falls due to the lack of midrails and endrails.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 238350)
JAMESTOWN, RI—2026-07-10
A K I CARPENTRY INC
BROOKLYN, NY—2026-07-08
PALACE RESIDENTIAL CORP.
BROOKLYN, NY—2026-07-07
PRO PROPERTY RENO INC.
KENTON, OH—2026-07-01
SUNLIGHT WINDOWS AND EXTERIORS, LLC
ROBBINSVILLE, NJ—2026-06-30
FAST WRAP WINDOWS & DOORS, INC.
More inspections in IL
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
GRANITE CITY, IL—2026-07-13
UNITED STATES STEEL CORPORATION
DECATUR, IL—2026-07-10
TILLAMOOK ILLINOIS, LLC
NEW LENOX, IL—2026-07-10
A.D GENERAL CONSTRUCTION LLC
LOCKPORT, IL—2026-07-09
ROBERTO GOMEZ DBA ROBERTO GOMEZ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339583163.