Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,913,242Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CHEROKEE PUMPING OF FLORIDA LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of CHEROKEE PUMPING OF FLORIDA LLC in 3760 BIRD RD, MIAMI, FL 33146 (NAICS 238110). OSHA activity number 339597338.

Watch Cherokee Pumping OF Florida LLC — free Get an email when a new federal OSHA severe-injury report for Cherokee Pumping OF Florida LLC is published. One employer, no account, unsubscribe in one click.
Site address
3760 BIRD RD
City
MIAMI
State
FL
ZIP
33146
Mailing
6511 NOVA DRIVE #285, DAVIE, FL 33317
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238110
Employees
1
Ownership type
A

2 citations on file for this inspection.

1926.21 B02

Serious Gravity 10 1 instance 3 exposed
Issued
Penalty
Initial $2800.00 · Current $1680.00 Reduced
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury:    On or about February 21, 2014, at the above address jobsite, the employer did not provide training to a concrete boom pump truck operator who was exposed to hazards such as but not limited to electrical shock from overhead power lines of 138 kV.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1926.600 A06 II

Serious Gravity 10 1 instance 3 exposed
Issued
Penalty
Initial $2800.00 · Current $1680.00 Reduced
29 CFR 1926.600(a)(6)(ii): For lines rated over 50 kV, minimum clearance between the lines and any part of the crane or load were not 10 feet plus 0.4 inch for each 1 kV over 50 kV, or twice the length of the line insulator, but never less than 10 feet:    On or about February 21, 2014, at the above address jobsite, the employer had placed a concrete boom pump truck at less than the required 45.2 ft from the overhead 138kV power lines.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

View CHEROKEE PUMPING OF FLORIDA LLC's full OSHA safety record →