Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,913,242Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: ALM TECH GROUP

Follow-up inspection · Safety discipline

On , OSHA opened a follow-up safety inspection of ALM TECH GROUP in 975 N. SERVICE ROAD WEST, SULLIVAN, MO 63080 (NAICS 336413). OSHA activity number 339599300.

Watch ALM Tech Group — free Get an email when a new federal OSHA severe-injury report for ALM Tech Group is published. One employer, no account, unsubscribe in one click.
Establishment
ALM TECH GROUP
Site address
975 N. SERVICE ROAD WEST
City
SULLIVAN
State
MO
ZIP
63080
Mailing
975 N. SERVICE ROAD WEST, SULLIVAN, MO 63080
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336413
Employees
31
Ownership type
A

13 citations on file for this inspection.

1910.147 C05 I

Serious Gravity 10 1 instance 15 exposed
Issued
Abate by
Penalty
Initial $5390.00 · Current $2695.00 Reduced
29 CFR 1910.147(c)(5)(i):  Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware were not provided by the employer for isolating, securing, or blocking of machines or equipment from energy sources:    Inside of the Milling Department, specific lockout devices were not purchased or utilized for isolating the hydraulic and/or pneumatic energy sources for the following machines:    a/  Okuma CNC Lathe, m/n MC-V4020, s/n, 0832-12/2005, 240 volts, 90 p.s.i. pneumatics.    b/  MAZAK CNC Milling Machine, m/n Vortex 815/120, s/n 153125, 240 volts, 90 p.s.i. pneumatics, and hydraulics.    c.  MAZAK CNC Milling Machine, m/n VTC-300C, s/n 162632, 240 volts, 90 p.s.i. pneumatics.      d.  MAZAK CNC Milling Machine, m/n MT-V515, s/n 105081, 240 volts, 90 p.s.i. pneumatics and hydraulics.    e.  Okuma Cadet-Mate CNC Milling Machine, m/n unknown s/n, 0334, 240 volts, 90 p.s.i. pneumatics.    Inside of the Lathe Department, specific lockout devices were not purchased or utilized for isolating the hydraulic and/or pneumatic energy sources for the following machines:    a/  MAZAK 6-Axis Quick Turn Nexus CNC Lathe, m/n QTN 250MSY, s/n 174319, 240 volts, 90 p.s.i. pneumatics.    b/  MAZAK Quick Turn 18N CNC Lathe, m/n QT-18-N-INIV-K, s/n 106851, 240 volts, 90 p.s.i. pneumatics.    c/  MAZAK Viper CNC Lathe, m/n VMC 3000 GX7, s/n, 2780, 240 volts, 90 p.s.i. pneumatics.
Recent events (2)
  • — I (S) $2695
  • — Z (S) $5390

1910.212 B

Serious Gravity 10 2 instances 15 exposed
Issued
Abate by
Penalty
Initial $5390.00 · Current $2695.00 Reduced
29 CFR 1910.212(b): Machines designed for a fixed location were not securely anchored to prevent walking or moving:    Inside of the Milling Department, the following machines were not anchored to the concrete floor:    a/  JET 8" Pedestal Mounted Buffing Machine, m/n JBG-8A, s/n 12020168.    b/  JET 8" Pedestal Mounted Abrasive Wheel Grinder, m/n JBG-8A, s/n 12041591.
Recent events (2)
  • — I (S) $2695
  • — Z (S) $5390

1910.147 C04 I

Repeat Gravity 10 8 instances 15 exposed
Issued
Abate by
Penalty
Initial $10780.00 · Current $5390.00 Reduced
29 CFR 1910.147(c)(4)(i):  Procedures were not developed, documented, and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    Inside of the Milling Department, specific lockout/tagout procedures were not developed, documented, or implemented for the following machines:      a/  Okuma CNC Lathe, m/n MC-V4020, s/n, 0832-12/2005, 240 volts, 90 p.s.i. pneumatics.    b/  MAZAK CNC Milling Machine, m/n Vortex 815/120, s/n 153125, 240 volts, 90 p.s.i. pneumatics, and hydraulics.    c.  MAZAK CNC Milling Machine, m/n VTC-300C, s/n 162632, 240 volts, 90 p.s.i. pneumatics.      d.  MAZAK CNC Milling Machine, m/n MT-V515, s/n 105081, 240 volts, 90 p.s.i. pneumatics, and hydraulics.    e.  Okuma Cadet-Mate CNC Milling Machine, m/n unknown s/n, 0334, 240 volts, 90 p.s.i. pneumatics.    Inside of the Lathe Department, specific lockout/tagout procedures were not developed, documented, or implemented for the following machines:    a/  MAZAK 6-Axis Quick Turn Nexus CNC Lathe, m/n QTN 250MSY, s/n 174319, 240 volts, 90 p.s.i. pneumatics.    b/  MAZAK Quick Turn 18N CNC Lathe, m/n QT-18-N-INIV-K, s/n 106851, 240 volts, 90 p.s.i. pneumatics.    c/  MAZAK Viper CNC Lathe, m/n VMC 3000 GX7, s/n, 2780, 240 volts, 90 p.s.i. pneumatics.      ALM TECH GROUP was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1910.147(c)(4)(i), which was contained in OSHA inspection number 315979740, citation number 1, item number 1 and was affirmed as a final order on 05/24/12, with respect to a workplace located at 975 N. Service Road West, Sullivan, MO 63080.
Recent events (2)
  • — I (R) $5390
  • — Z (R) $10780

1910.147 C06 I

Repeat Gravity 10 8 instances 15 exposed
Issued
Abate by
Penalty
Initial $10780.00 · Current $5390.00 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:    Periodic inspections of the energy control procedures were not performed for the purpose of correcting deviations and inadequacies such as the failure to fully de-energize machines as required, ensuring that newly hired employees were trained, updating or adding specific procedures, and to conduct a review, by the inspector of the program, of each authorized employee's responsibilities in performing lockout/tagout according to the procedures being reviewed.  The following machines were affected:       a/  Okuma CNC Lathe, m/n MC-V4020, s/n, 0832-12/2005, 240 volts, 90 p.s.i. pneumatics.    b/  MAZAK CNC Milling Machine, m/n Vortex 815/120, s/n 153125, 240 volts, 90 p.s.i. pneumatics, and hydraulics.    c.  MAZAK CNC Milling Machine, m/n VTC-300C, s/n 162632, 240 volts, 90 p.s.i. pneumatics.      d.  MAZAK CNC Milling Machine, m/n MT-V515, s/n 105081, 240 volts, 90 p.s.i. pneumatics, and hydraulics.    e.  Okuma Cadet-Mate CNC Milling Machine, m/n unknown s/n, 0334, 240 volts, 90 p.s.i. pneumatics.    Inside of the Lathe Department, specific lockout/tagout procedures were not developed, documented, or implemented for the following machines:    a/  MAZAK 6-Axis Quick Turn Nexus CNC Lathe, m/n QTN 250MSY, s/n 174319, 240 volts, 90 p.s.i. pneumatics.    b/  MAZAK Quick Turn 18N CNC Lathe, m/n QT-18-N-INIV-K, s/n 106851, 240 volts, 90 p.s.i. pneumatics.    c/  MAZAK Viper CNC Lathe, m/n VMC 3000 GX7, s/n, 2780, 240 volts, 90 p.s.i. pneumatics.       ALM TECH GROUP was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1910.147(c)(6)(i), which was contained in OSHA inspection number 315979740, citation number 1, item number 2, and was affirmed as a final order on 05/24/12, with respect to a workplace located at 975 N. Service Road West, Sullivan, MO 63080.    ALM TECH GROUP was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1910.147(c)(6)(i), which was contained in OSHA inspection number 313900391, citation number 1, item number 2, and was affirmed as a final order on 02/11/10, with respect to a workplace located at 975 N. Service Road West, Sullivan, MO 63080.
Recent events (2)
  • — I (R) $5390
  • — Z (R) $10780

1910.147 C07 I A

Repeat Gravity 10 1 instance 15 exposed
Issued
Abate by
Penalty
Initial $10780.00 · Current $5390.00 Reduced
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation:    Inside of the Milling Department, authorized employees were unfamiliar with the specific lockout/tagout procedures required to effectively isolate the following machines from their energy sources:        a/  Okuma CNC Lathe, m/n MC-V4020, s/n, 0832-12/2005, 240 volts, 90 p.s.i. pneumatics.    b/  MAZAK CNC Milling Machine, m/n Vortex 815/120, s/n 153125, 240 volts, 90 p.s.i. pneumatics, and hydraulics.    c.  MAZAK CNC Milling Machine, m/n VTC-300C, s/n 162632, 240 volts, 90 p.s.i. pneumatics.      d.  MAZAK CNC Milling Machine, m/n MT-V515, s/n 105081, 240 volts, 90 p.s.i. pneumatics, and hydraulics.    e.  Okuma Cadet-Mate CNC Milling Machine, m/n unknown s/n, 0334, 240 volts, 90 p.s.i. pneumatics.    Inside of the Lathe Department, authorized employees were unfamiliar with the specific lockout/tagout procedures required to effectively isolate the following machines from their energy sources:    a/  MAZAK 6-Axis Quick Turn Nexus CNC Lathe, m/n QTN 250MSY, s/n 174319, 240 volts, 90 p.s.i. pneumatics.    b/  MAZAK Quick Turn 18N CNC Lathe, m/n QT-18-N-INIV-K, s/n 106851, 240 volts, 90 p.s.i. pneumatics.    c/  MAZAK Viper CNC Lathe, m/n VMC 3000 GX7, s/n, 2780, 240 volts, 90 p.s.i. pneumatics.       ALM TECH GROUP was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1910.147(c)(7)(i)(A), which was contained in OSHA inspection number 315979740, citation number 1, item number 3a and was affirmed as a final order on 05/24/12, with respect to a workplace located at 975 N. Service Road West, Sullivan, MO 63080.
Recent events (2)
  • — I (R) $5390
  • — Z (R) $10780

1910.147 D01

Repeat Gravity 10 8 instances 15 exposed
Issued
Abate by
Penalty
Initial $10780.00 · Current $5390.00 Reduced
29 CFR 1910.147(d)(1): The authorized employee did not have knowledge of the type and magnitude of the energy, the hazards of the energy to be controlled, and the method or means to control the energy before the authorized or affected employee turned off:      a/  Employees that operated machinery such as, but not limited to, the MAZAK CNC Machine, m/n Vortex 815/120, s/n 153125, were not aware of all of the energy sources, the hazards of these energy sources, and how to control the energy sources, such as through the use of a suitable lockout/tagout device.     ALM TECH GROUP was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1910.147(d)(1), which was contained in OSHA inspection number 315979740, citation number 1, item number 4a and was affirmed as a final order on 05/24/12, with respect to a workplace located at 975 N. Service Road West, Sullivan, MO 63080.
Recent events (2)
  • — I (R) $5390
  • — Z (R) $10780

1910.147 D03

Repeat Gravity 10 8 instances 15 exposed
Issued
Abate by
Penalty
Initial $10780.00 · Current $5390.00 Reduced
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s):    Energy isolating devices for hydraulic and/or pneumatic energy sources were not physically located and operated for the following machines:          a/  Okuma CNC Lathe, m/n MC-V4020, s/n, 0832-12/2005, 240 volts, 90 p.s.i. pneumatics.    b/  MAZAK CNC Milling Machine, m/n Vortex 815/120, s/n 153125, 240 volts, 90 p.s.i. pneumatics, and hydraulics.    c.  MAZAK CNC Milling Machine, m/n VTC-300C, s/n 162632, 240 volts, 90 p.s.i. pneumatics.      d.  MAZAK CNC Milling Machine, m/n MT-V515, s/n 105081, 240 volts, 90 p.s.i. pneumatics, and hydraulics.    e.  Okuma Cadet-Mate CNC Milling Machine, m/n unknown s/n, 0334, 240 volts, 90 p.s.i. pneumatics.    f/  MAZAK 6-Axis Quick Turn Nexus CNC Lathe, m/n QTN 250MSY, s/n 174319, 240 volts, 90 p.s.i. pneumatics.    g/  MAZAK Quick Turn 18N CNC Lathe, m/n QT-18-N-INIV-K, s/n 106851, 240 volts, 90 p.s.i. pneumatics.    h/  MAZAK Viper CNC Lathe, m/n VMC 3000 GX7, s/n, 2780, 240 volts, 90 p.s.i. pneumatics.      ALM TECH GROUP was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1910.147(d)(3), which was contained in OSHA inspection number 315979740, citation number 1, item number 4c and was affirmed as a final order on 05/24/12, with respect to a workplace located at 975 N. Service Road West, Sullivan, MO 63080.
Recent events (2)
  • — I (R) $5390
  • — Z (R) $10780

1910.147 D04 I

Repeat Gravity 10 8 instances 15 exposed
Issued
Abate by
Penalty
Initial $10780.00 · Current $5390.00 Reduced
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:    Suitable lockout/tagout devices were not applied to the residual energy sources belonging to the following machines:    a/  Okuma CNC Lathe, m/n MC-V4020, s/n, 0832-12/2005, 240 volts, 90 p.s.i. pneumatics.    b/  MAZAK CNC Milling Machine, m/n Vortex 815/120, s/n 153125, 240 volts, 90 p.s.i. pneumatics, and hydraulics.    c.  MAZAK CNC Milling Machine, m/n VTC-300C, s/n 162632, 240 volts, 90 p.s.i. pneumatics.      d.  MAZAK CNC Milling Machine, m/n MT-V515, s/n 105081, 240 volts, 90 p.s.i. pneumatics, and hydraulics.    e.  Okuma Cadet-Mate CNC Milling Machine, m/n unknown s/n, 0334, 240 volts, 90 p.s.i. pneumatics.    f/  MAZAK 6-Axis Quick Turn Nexus CNC Lathe, m/n QTN 250MSY, s/n 174319, 240 volts, 90 p.s.i. pneumatics.    g/  MAZAK Quick Turn 18N CNC Lathe, m/n QT-18-N-INIV-K, s/n 106851, 240 volts, 90 p.s.i. pneumatics.    h/  MAZAK Viper CNC Lathe, m/n VMC 3000 GX7, s/n, 2780, 240 volts, 90 p.s.i. pneumatics.      ALM TECH GROUP was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1910.147(d)(4)(i), which was contained in OSHA inspection number 315979740, citation number 1, item number 5, and was affirmed as a final order on 05/24/12, with respect to a workplace located at 975 N. Service Road West, Sullivan, MO 63080.
Recent events (2)
  • — I (R) $5390
  • — Z (R) $10780

1910.212 A01

Repeat Gravity 10 2 instances 15 exposed
Issued
Abate by
Penalty
Initial $10780.00 · Current $5390.00 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    Inside of the Milling Department, the interlock guarding device belonging to the following machines was non-operational:    a/  MAZAK CNC Milling Machine, m/n Vortex 815/120, s/n 153125.    b/  MAZAK Viper CNC Milling Machine, m/n VMC 3000 GX7, s/n 2780.    Employee(s) operating these machines could easily open up the access door thereby exposing themselves to the hazard(s) of flying chips or parts or rotating parts.    ALM TECH GROUP was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1910.212(a), which was contained in OSHA inspection number 315979740, citation number 1, item number 6 and was affirmed as a final order on 05/24/12, with respect to a workplace located at 975 N. Service Road West, Sullivan, MO 63080.
Recent events (2)
  • — I (R) $5390
  • — Z (R) $10780

1904.40 A

Deleted Other-than-serious 4 instances 31 exposed
Issued
Abate by
Penalty
Initial $770.00 · Current $0.00 Reduced
29 CFR 1904.40(a): The employer did not provide an authorized government representative the records within the four business hours:  a/  The employer failed to provide the OSHA compliance Officer with a copy of the OSHA 300 Form, Log of Work Related Injury and Illnesses, and the OSHA 300A Form, Summary of Work-Related Injuries and Illnesses, for calendar years 2011, 2012, 2013, and year-to-date 2014, when requested on 02/25/14 and again on 03/11/14.
Recent events (2)
  • — I (O) $0
  • — Z (O) $770

1910.147 C04 II

Deleted Other-than-serious 1 instance 15 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(4)(ii): Energy control procedures did not provide a means to enforce compliance:  a/  The written lockout/tagout program did not provide a means to enforce compliance.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.147 C06 II

Deleted Other-than-serious 8 instances 15 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed:  a/  Certification that periodic audits of the specific, written energy control procedures had not been performed.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.147 C07 IV

Deleted Other-than-serious 1 instance 15 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(7)(iv): The employer did not certify that employee training had been accomplished and kept up to date:  a/  Employee training in the lockout/tagout program had not been certified that also included the employee's name and date(s) of training.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339599300.