Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: ENSIGN US DRILLING (SW) INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ENSIGN US DRILLING (SW) INC. in WOLFBONE (TREND AREA) FIELD, REEVES TXL FEE T8-51-11 LEASE, WELL #1, ENSIGN US SOUTHERN DRILLING RIG #759, 19.08 MILES SE OF PECOS, PECOS, TX 79772 (NAICS 213111). OSHA activity number 339607681.

Watch Ensign US Drilling (SW) INC. — free Get an email when a new federal OSHA severe-injury report for Ensign US Drilling (SW) INC. is published. One employer, no account, unsubscribe in one click.
Site address
WOLFBONE (TREND AREA) FIELD, REEVES TXL FEE T8-51-11 LEASE, WELL #1, ENSIGN US SOUTHERN DRILLING RIG #759, 19.08 MILES SE OF PECOS
City
PECOS
State
TX
ZIP
79772
Mailing
9300 TELEPHONE RD., HOUSTON, TX 77075
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213111
Employees
26
Ownership type
A

2 citations on file for this inspection.

1910.219 C02 I

Other-than-serious 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $3400.00 · Current $3400.00
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting:     Rig #759: on or about February 25, 20214, the shaft guard was missing from between the diesel motor and generating plant on all three generators, exposing employees to caught-in hazards.
Recent events (2)
  • — I (O) $3400
  • — Z (S) $3400

1910.305 A02 XI

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $3400.00 · Current $3400.00
29 CFR 1910.305(a)(2)(xi): Cable assemblies and flexible cords and cables were not supported in place at intervals that ensure that they will be protected from physical damage:     Rig #759: on or about February 25, 2014, 480 volt conductors from the tray to the drill water pump #2 were not supported adequately to protect against physical damage.
Recent events (2)
  • — I (O) $3400
  • — Z (S) $3400

View ENSIGN US DRILLING (SW) INC.'s full OSHA safety record →