TALLAHASSEE, FL —
OSHA Inspection: TONY WILLIAMS DRYWALL AND PAINTING, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of TONY WILLIAMS DRYWALL AND PAINTING, INC. in LOT 5 PERSIMMON DR, TALLAHASSEE, FL 32312 (NAICS 238140). OSHA activity number 339608135.
Where did this inspection happen?
- Establishment
- TONY WILLIAMS DRYWALL AND PAINTING, INC.
- Site address
- LOT 5 PERSIMMON DR
- City
- TALLAHASSEE
- State
- FL
- ZIP
- 32312
- Mailing
- 8513 RAQUEL LN, TALLAHASSEE, FL 32312
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 15
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 B01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): a. On or about February 27, 2014, on the north side of the house, employees installing stucco to the face of the house were using a scaffold that was not fully planked, exposing themselves to a 6 feet, 7 inch fall hazard.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1926.451 C02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: a. On or about February 27, 2014, on the north side of the house, employees installing stucco to the face of the house were using a scaffold that did not have an adequate firm foundation, exposing themselves to a 6 feet, 7 inch fall hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 C03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(c)(3): Supported scaffold poles, legs, post, frames, and/or uprights were not plumb and braced to prevent swaying and displacement: a. On or about February 27, 2014, on the north side of the house, employees installing stucco to the face of the house were using a scaffold that was not plumb, exposing themselves to a 6 feet, 7 inch fall hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.100 A
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a. On or about February 27, 2014, on the north side of the house, employees working beneath employees installing stone to the facing of the house were not wearing hard hats, exposing themselves to the hazard of being struck by falling debris.
Recent events (2)
- — Z (O) $0
- — I (O) $0
More inspections in this industry (NAICS 238140)
MARIANNA, FL—2026-07-13
PRIMETIME MOBILE MASONRY LLC
LOMPOC, CA—2026-07-10
UNKNOWN EMPLOYER
FREEHOLD, NJ—2026-07-10
CRAIG'S MASONRY & HARDSCAPE LLC
CINCINNATI, OH—2026-07-09
ALL AMERICAN CONCRETE LLC
NEW YORK, NY—2026-07-08
JEY CONSTRUCTIONS WORKS CORP
More inspections in FL
MARIANNA, FL—2026-07-13
PRIMETIME MOBILE MASONRY LLC
MELBOURNE, FL—2026-07-13
OMNIPOTENT BRANDS, LLC
QUINCY, FL—2026-07-13
WALMART
INDIAN ROCKS BEACH, FL—2026-07-10
UNKNOWN CONTRACTOR
CLEARWATER, FL—2026-07-10
ROOFTECH ROOFING & WATERPROOFING INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339608135.