ROOSEVELT ISLAND, NY —
OSHA Inspection: WINDSTRUCT INC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of WINDSTRUCT INC in 531 MAIN ST, ROOSEVELT ISLAND, NY 10044 (NAICS 238150). OSHA activity number 339615924.
Where did this inspection happen?
- Establishment
- WINDSTRUCT INC
- Site address
- 531 MAIN ST
- City
- ROOSEVELT ISLAND
- State
- NY
- ZIP
- 10044
- Mailing
- 3801 23RD AVE # 307, LONG ISLAND CITY, NY 11105
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238150
- Employees
- 12
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.404 B01 I
- Issued
- Penalty
- Initial $1200.00 · Current $900.00 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(i): General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors. a) Apt 716: On or about March 7, 2014 The window installer was using a Hilti SD 4500 Drywall Screwdriver with an extension cord but there was no GFI being used.
Recent events (2)
- — I (S) $900
- — Z (S) $1200
1926.405 A02 II J
- Issued
- Penalty
- Initial $1200.00 · Current $900.00 Reduced
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(J): Extension cord sets used with portable electric tools and appliances shall be of three-wire type and shall be designed for hard or extra-hard usage. Flexible cords used with temporary and portable lights shall be designed for hard or extra-hard usage. NOTE: The National Electrical Code, ANSI/NFPA 70, in Article 400, Table 400-4, lists various types of flexible cords, some of which are noted as being designed for hard or extra-hard usage. Examples of these types of flexible cords include hard service cord (types S, ST, SO, STO) and junior hard service cord (types SJ, SJO, SJT, SJTO) a) Apt 716: On or about March 7, 2014 The window installer was using a Hilti Screwdriver with an extension cord but the cord was a 2 wire type which was not approved for hard usage.
Recent events (2)
- — I (S) $900
- — Z (S) $1200
More inspections at WINDSTRUCT INC
NEW YORK, NY—2010-10-07 00:00:00
WINDSTRUCT INC.
NEW YORK, NY—2009-12-15 00:00:00
WINDSTRUCT INC.
BROOKLYN, NY—2007-01-18 00:00:00
WINDSTRUCT INC.
BROOKLYN, NY—2006-06-13 00:00:00
WINDSTRUCT INC.
NEWARK, NJ—2006-01-10 00:00:00
WINDSTRUCT, INC
View WINDSTRUCT INC's full OSHA safety record →
More inspections in this industry (NAICS 238150)
BRIDGEPORT, WV—2026-07-14
AMERICAN PLATE GLASS, INC.
HARRISBURG, PA—2026-07-02
HERSHOCKS INC
HARRISBURG, PA—2026-07-02
HERSHOCKS INC
HOLLISTER, CA—2026-06-29
PAC CON GLAZING. INC.
SAN ANTONIO, TX—2026-06-24
ARROWALL COMPANY
More inspections in NY
MAYVILLE, NY—2026-07-16
MAYVILLE VILLAGE DPW
NEW HYDE PARK, NY—2026-07-16
NORTH HEMPSTEAD TN MICHAEL J TULLY PARK
CONESUS, NY—2026-07-16
CONESUS TN HIGHWAY DEPT
COMSTOCK, NY—2026-07-15
NYSDOCCS WASHINGTON CORRECTIONAL FACILITY
BALDWINSVILLE, NY—2026-07-15
LYSANDER TOWN HIGHWAY DEPARTMENT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339615924.