Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: WINDSTRUCT INC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of WINDSTRUCT INC in 531 MAIN ST, ROOSEVELT ISLAND, NY 10044 (NAICS 238150). OSHA activity number 339615924.

Watch Windstruct INC — free Get an email when a new federal OSHA severe-injury report for Windstruct INC is published. One employer, no account, unsubscribe in one click.
Establishment
WINDSTRUCT INC
Site address
531 MAIN ST
City
ROOSEVELT ISLAND
State
NY
ZIP
10044
Mailing
3801 23RD AVE # 307, LONG ISLAND CITY, NY 11105
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238150
Employees
12
Ownership type
A

2 citations on file for this inspection.

1926.404 B01 I

Serious Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $1200.00 · Current $900.00 Reduced
29 CFR 1926.404(b)(1)(i): General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.          a) Apt 716:      On or about March 7, 2014      The window installer was using a Hilti SD 4500 Drywall Screwdriver with an extension cord but there was no GFI being used.
Recent events (2)
  • — I (S) $900
  • — Z (S) $1200

1926.405 A02 II J

Serious Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $1200.00 · Current $900.00 Reduced
29 CFR 1926.405(a)(2)(ii)(J): Extension cord sets used with portable electric tools and appliances shall be of three-wire type and shall be designed for hard or extra-hard usage. Flexible cords used with temporary and portable lights shall be designed for hard or extra-hard usage.  NOTE: The National Electrical Code, ANSI/NFPA 70, in Article 400, Table 400-4, lists various types of flexible cords, some of which are noted as being designed for hard or extra-hard usage. Examples of these types of flexible cords include hard service cord (types S, ST, SO, STO) and junior hard service cord (types SJ, SJO, SJT, SJTO)      a) Apt 716:      On or about March 7, 2014      The window installer was using a  Hilti Screwdriver with an extension cord but the cord was a 2 wire type which was not approved for hard usage.
Recent events (2)
  • — I (S) $900
  • — Z (S) $1200

View WINDSTRUCT INC's full OSHA safety record →