HANOVER, PA —
OSHA Inspection: SHEA ROOFING
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SHEA ROOFING in 135 SANFORD AVE, HANOVER, PA 17331 (NAICS 238160). OSHA activity number 339617664.
Where did this inspection happen?
- Establishment
- SHEA ROOFING
- Site address
- 135 SANFORD AVE
- City
- HANOVER
- State
- PA
- ZIP
- 17331
- Mailing
- 90 NORTH DONNERVILLE ROAD, MOUNTVILLE, PA 17754
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 6
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.153 H04
- Issued
- Abate by
- Penalty
- Initial $2100.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.153(h)(4): Regulators were not either directly connected to the container valves or to manifolds connected to the container valves: (a) Baresville Elementary School West Side of Building - The LP gas hose was installed between the tank and the kettle with the regulator located at the kettle instead of at the LP tank. LP gas at full tank pressure flowed from the tank through the hose on or about March 7, 2014. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $2100
1926.502 F01
- Issued
- Penalty
- Initial $3500.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.502(f)(1): Warning lines were not erected around all sides of the roof work area: (a) Baresville Elementary School Roof - The warning line was not maintained around all sides of the roof work area. Employees worked on the roof to install the multi layered built-up roof system and were exposed to a fall hazard of 12 feet from the eve to the ground on or about March 7, 2014. No abatement certification or documentation required.
Recent events (2)
- — I (S) $0
- — Z (S) $3500
1926.502 F01 I
- Issued
- Penalty
- Initial $0.00 · Current $2100.00
General-duty citation text
29 CFR 1926.502(f)(1)(i): When no mechanical equipment was being used the warning line was not erected at least 6 feet (1.8m) from the roof edge: (a) Baresville Elementary School Roof - The warning line was not maintained at least six feet from the roof edge. Employees worked on the roof to install the multi layered built-up roof system and were exposed to a fall hazard of 12 feet from the eve to the ground on or about March 7, 2014. No abatement certification or documentation required.
Recent events (2)
- — I (S) $2100
- — Z (S) $0
1926.502 F01 III
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.502(f)(1)(iii): Points of access, material handling areas, storage areas, and/or hoisting areas were not connected to the work area by an access path formed by two warning lines: (a) Baresville Elementary School Roof - The point of access was not connected to the work area by an access path formed by two warning lines. Employees worked on the roof to install the multi layered built-up roof system and were exposed to a fall hazard of 12 feet from the eve to the ground on or about March 7, 2014. (b) Baresville Elementary School Roof - The material handling area was not connected to the work area by an access path formed by two warning lines. Employees worked on the roof to install the multi layered built-up roof system and were exposed to a fall hazard of 12 feet from the eve to the ground on or about March 7, 2014. No abatement certification or documentation required. No abatement certification or documentation required.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 H03 IV
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(h)(3)(iv): The employer did not produce a hazard communication program that included an explanation of the labels received on shipped containers and the workplace labeling system used by their employer and the safety data sheet, including the order of information and how the employee could obtain and use the appropriate hazard information: (a) Baresville Elementary School Roof - The employer did not provide employees with training on the revised hazard communication standard (HCS 2012) label elements and the new format and type of information on each section of the safety data sheets (SDSs) to ensure that when employees begin to see HCS 2012 compliant labels and SDSs in their workplace, employees understand how to use the labels and SDSs and access the information effectively on or about March 7, 2014. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at SHEA ROOFING
EPHRATA, PA—2007-10-22 00:00:00
SHEA ROOFING
RED LION, PA—2007-06-29 00:00:00
SHEA ROOFING
HARRISBURG, PA—2007-01-12 00:00:00
SHEA ROOFING
PENNSAUKEN, NJ—2006-06-02 00:00:00
SHEA ROOFING
HERSHEY, PA—2006-01-19 00:00:00
SHEA ROOFING
View SHEA ROOFING's full OSHA safety record →
More inspections in this industry (NAICS 238160)
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.
HENDERSON, NV—2026-07-13
INTEGRITY ROOFING LLC
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CAMDEN, OH—2026-07-13
ALBERTO MORALES
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.