Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PRIMA AMERICA CORPORATION

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of PRIMA AMERICA CORPORATION in 248 STATE STREET, GROVETON, NH 03582 (NAICS 237130). OSHA activity number 339620502.

Watch Prima America Corporation — free Get an email when a new federal OSHA severe-injury report for Prima America Corporation is published. One employer, no account, unsubscribe in one click.
Site address
248 STATE STREET
City
GROVETON
State
NH
ZIP
03582
Mailing
PO BOX 274, GROVETON, NH 03582
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237130
Employees
1
Ownership type
A

7 citations on file for this inspection.

1926.20 B02

Serious Gravity 10 1 instance 12 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1200.00 Reduced
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s):    a. Site- Workers were exposed to fall, struck by, forklift, trip, electrical, and fire hazards where the controlling contractor failed to provide for frequent and regular inspections of the jobsite conducted by a competent person.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2800

1926.150 C01 VI

Serious Gravity 5 1 instance 12 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.150(c)(1)(vi): A fire extinguisher, rated not less than 10B, was not provided within 50 feet of wherever more than 5 gallons of flammable or combustible liquids or 5 pounds of flammable gas were being used on the jobsite:  a. Site- Workers were not protected from fire hazards where the controlling contractor failed to ensure that fire extinguishers were available when combustible fuel was stored next to an operating portable kerosene heater. The combustible fuel and heater was located in a temporary room with walls made of non-fire retardant plastic sheeting.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.405 A02 II C

Serious Gravity 1 1 instance 12 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.405(a)(2)(ii)(C): Receptacles for uses other than temporary lighting were installed on branch circuits which supplied temporary lighting:  a. Site- The controlling contractor failed to ensure that workers inside two stairways with no natural lighting were protected from trip hazards where temporary string lights were plugged into temporary electric receptacles that provided temporary power to tools and equipment.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.25 A

Serious Gravity 5 1 instance 12 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $960.00 Reduced
29 CFR 1926.25(a): During the course of construction, alteration, or repairs,  debris was not kept cleared from work areas, passageways, and stairs, in and around buildings or other structures:    a. Site- The controlling contractor failed to ensure that workers were protected from trip, laceration, and trip hazards where construction debris was not picked up on a regular basis. Each level inside the tower has metal floor grating where small pieces of sheet metal and steel plate was left on the floor and could pass through the floor grating striking workers on lower working levels.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1926.451 B04

Serious Gravity 5 1 instance 12 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1200.00 Reduced
29 CFR 1926.451(b)(4): Each end of a platform, not cleated or otherwise restrained by hooks or equivalent means, did not extend over the centerline of its support at least 6 inches (15 cm):    a. Site-The controlling contractor failed to ensure that their scaffold platforms that were erected spanning between structural steel in the tower extended more than six inches beyond the centerline of their steel supports.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1926.501 B01

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems:  a. Roof- The controlling contractor failed to ensure that workers on the roof were protected from a fall of approximately 70 feet.
Recent events (2)
  • — I (S) $2800
  • — Z (S) $2800

1926.602 D

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $0.00 Reduced
29 CFR 1926.602(d): The employer did not certify that each operator had been trained and evaluated as required by paragraph 29 CFR 1910.178(l):Note: The requirements applicable to construction work under paragraph (d) of this section are identical to those set forth at paragraph (l) of 29 CFR 1910.178:    a. Site- The controlling contractor failed to ensure that workers operating their Nissan forklift were provided with operator training.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339620502.