GREENFIELD, MA —
OSHA Inspection: TRANS WORLD ENTERTAINMENT CORPORATION
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of TRANS WORLD ENTERTAINMENT CORPORATION in 238 MAIN ST, GREENFIELD, MA 01301 (NAICS 453998). OSHA activity number 339622706.
Where did this inspection happen?
- Establishment
- TRANS WORLD ENTERTAINMENT CORPORATION
- Site address
- 238 MAIN ST
- City
- GREENFIELD
- State
- MA
- ZIP
- 01301
- Mailing
- 238 MAIN ST, GREENFIELD, MA 01301
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 453998
- Employees
- 7
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.22 D01
- Issued
- Abate by
- Penalty
- Initial $3000.00 · Current $3000.00
General-duty citation text
29 CFR 1910.22(d)(1): In every building or other structure, or part thereof, used for mercantile, business, industrial, or storage purposes, the loads approved by the building official were not marked in a conspicuous place in each space to which they related: (a) Storeroom: On or about 3/10/14, the load rating for the loft was not marked in a conspicuous place.
Recent events (1)
- — Z (S) $3000
1910.23 A01
- Issued
- Abate by
- Penalty
- Initial $5000.00 · Current $5000.00
General-duty citation text
29 CFR 1910.23(a)(1): Every stairway floor opening was not guarded by a standard railing constructed in accordance with paragraph (e) of this section on all exposed sides (except at the entrance to the stairway): (a) Storeroom: On or about 3/10/14, the stairway floor opening in the loft was not guarded by a standard railing.
Recent events (1)
- — Z (S) $5000
1910.23 C01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards: (a) Storeroom: On or about 3/10/14, the open side of the loft was not guarded with a railing (or equivalent).
Recent events (1)
- — Z (S) $0
1910.24 D
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.24(d): Fixed stairways did not have a minimum width of 22 inches: (a) Storeroom: On or about 3/10/14, the width of the stairway to the loft was less than 22 inches.
Recent events (1)
- — Z (S) $0
1910.24 F
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.24(f): Rise height and tread width were not uniform throughout any flight of stairs including any foundation structure used as one or more treads of the stairs: (a) Storeroom: On or about 3/10/14, the stairway to the loft had treads which were missing, cracked, and broken.
Recent events (1)
- — Z (S) $0
1910.24 H
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.24(h): Standard railings were not provided on the open sides of all exposed stairways and stair platforms: (a) Storeroom: On or about 3/10/14, the open side of the stairway to the loft did not have a railing.
Recent events (1)
- — Z (S) $0
1910.25 D01 X
- Issued
- Abate by
- Penalty
- Initial $5000.00 · Current $5000.00
General-duty citation text
29 CFR 1910.25(d)(1)(x): Portable wood ladder(s) were not inspected frequently and those which had developed defects were not withdrawn from service for repair or destruction and tagged or marked as "Dangerous, Do Not Use." Storeroom: (a) On or about 3/10/14, the 8 foot portable wood ladder was unstable and had not been withdrawn from service for repair or destruction and tagged or marked as "Dangerous, Do Not Use." Storeroom: (b) On or about 3/10/14, the 10 foot portable wood ladder was pieced together with an extra piece of wood and had not been withdrawn from service for repair or destruction and tagged or marked as "Dangerous, Do Not Use."
Recent events (1)
- — Z (S) $5000
1910.334 B02
- Issued
- Abate by
- Penalty
- Initial $3000.00 · Current $3000.00
General-duty citation text
29 CFR 1910.334(b)(2): The repetitive manual reclosing of circuit breakers or reenergizing electric power and lighting circuits through replaced fuses was not prohibited: (a) Storeroom: On or about 3/10/14, the circuit breaker for the furnace was repetitively manually reclosed.
Recent events (1)
- — Z (S) $3000
More inspections in this industry (NAICS 453998)
QUINCY, FL—2026-07-13
WALMART
SUMMERVILLE, SC—2026-07-09
77568 - RACK ROOM SHOES
HARLEYSVILLE, PA—2026-07-09
TRACTOR SUPPLY CO.
WARWICK, RI—2026-07-09
LESLIE'S POOL SUPPLIES
OCEANSIDE, CA—2026-07-08
TARGET
More inspections in MA
WORCESTER, MA—2026-07-10
QUINSIGAMOND COMMUNITY COLLEGE
FITCHBURG, MA—2026-07-10
KELLEY WOOD PRODUCTS, INC.
EVERETT, MA—2026-07-10
HORIZON RETAIL CONSTRUCTION INC
NORTON, MA—2026-07-09
DYNAMIC RESIDENTIAL ROOF MARKETING, LLC
NORTON, MA—2026-07-09
LM GENERAL CONSTRUCTION INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339622706.