Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JENKINS HEATING & COOLING, LLC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JENKINS HEATING & COOLING, LLC. in NY HEART CENTER, 22670 SUMMIT DRIVE, WATERTOWN, NY 13601 (NAICS 238220). OSHA activity number 339625436.

Watch Jenkins Heating & Cooling, LLC. — free Get an email when a new federal OSHA severe-injury report for Jenkins Heating & Cooling, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
NY HEART CENTER, 22670 SUMMIT DRIVE
City
WATERTOWN
State
NY
ZIP
13601
Mailing
56 GLASBY ROAD, GOUVERNEUR, NY 13642
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
4
Ownership type
A

7 citations on file for this inspection.

1926.300 A

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $500.00 Reduced
29 CFR 1926.300(a): Hand tool(s), power tool(s) or similar equipment were not maintained in a safe condition:       a) South side of addition, store room, on or about 3-6-14:  One employee was using a table top miter saw with an inoperable/damaged protective guard.
Recent events (3)
  • — J (S) $500
  • — C (S) $1600
  • — Z (S) $1600

1926.304 F

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $500.00 Reduced
29 CFR  1926.304(f)  Section 4.1.2(b)  American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f):  Circular hand-fed rip saws were not equipped with a spreader to prevent material from squeezing the saw or being thrown back on the operator:         29 CFR 1926.304(f)  Section 4.1.2(c)  American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f):  Circular hand-fed rip saws did not have non-kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator:         29 CFR 1926.304(f)  Section 5.1.3.3  American National Standards Institute 01.1-1975, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f):  Electrically driven equipment was not equipped with magnetic switches or other devices that will prevent automatic restarting of the machine after a power failure:       a) South end of addition, store room, on or about 3-6-14:  Employees were ripping wood on a table saw that was not equipped with a spreader.       b) South end of addition, store room, on or about 3-6-14:  Employees were ripping wood on a table saw that was not equipped with non kick-back fingers or "dogs".       c) South end of addition, store room, on or about 3-6-14:  Employees were ripping wood on a table saw that was not equipped with a magnetic switch or anti-restart device.
Recent events (3)
  • — J (S) $500
  • — C (S) $1600
  • — Z (S) $1600

1926.304 I01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.304(i)(1): Each circular had-fed ripsaw was not guarded by a hood which completely enclosed that portion of the saw above the table and that portion of the saw above the material being cut:    a) South end of addition, store room, on or about 3-6-14:  Employees were ripping wood on a table saw that was not equipped with a hood guard that automatically adjusts to enclose the saw blade.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.404 B01 II

Serious Gravity 5 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $500.00 Reduced
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection:         a) Northwest corner of addition, on or about 3-6-14:  Employees were operating numerous power tools and equipment that were plugged into a power source that was not protected by a ground fault circuit interrupter (GFCI).
Recent events (3)
  • — J (S) $500
  • — C (S) $1600
  • — Z (S) $1600

1926.404 F06

Serious Gravity 5 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous:     a) Northwest corner of addition, on or about 3-6-14:  Employees were operating power tools and equipment that were plugged into two cords that did not have a continuous path to ground due to a missing a ground pin.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.1053 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $1600.00 · Current $500.00 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to upper landing surfaces, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladders were used to gain access:       a) South side of addition, store room, on or about 3-6-14:  One employee was using a fiberglass step ladder that was not extended 3 feet above the landing surface, exposing the employees to a fall hazard of  11 feet 10 inches.
Recent events (3)
  • — J (S) $500
  • — C (S) $1600
  • — Z (S) $1600

1926.1053 B13

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step:    a) South side of addition, store room, on or about 3-6-14:  One employee was accessing an attic area while standing on the top step and top platform of a fiberglass step ladder, exposing the employee to a fall hazard of 11 feet 10 inches.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339625436.