UMATILLA, FL —
OSHA Inspection: PRESTON POPP
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PRESTON POPP in 1 S CENTRAL AVE, UMATILLA, FL 32784 (NAICS 238350). OSHA activity number 339625501.
Where did this inspection happen?
- Establishment
- PRESTON POPP
- Site address
- 1 S CENTRAL AVE
- City
- UMATILLA
- State
- FL
- ZIP
- 32784
- Mailing
- 4400 NE 131ST STREET, ANTHONY, FL 32617
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238350
- Employees
- 5
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.451 B01 I
- Issued
- Penalty
- Initial $1020.00 · Current $510.00 Reduced
General-duty citation text
29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary: a. East wall - during framing operations on a welded frame scaffold, employees were exposed to an 11 foot fall hazard, in that, working platforms were not fully planked. There was a space that exceeded 9 and 1/4 inches between the platform and the uprights. Violation observed on or about 3/11/14.
Recent events (2)
- — I (S) $510
- — Z (S) $1020
1926.454 A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards: a. East wall - employees who used a welded frame scaffold during framing operations had not been trained in the safe use of the scaffold and the hazards associated with the use of the scaffold exposing employees to a fall hazard. Violation observed on or about 3/11/14.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 C02
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $600.00 Reduced
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: a. East wall - base plates were not used while scaffold posts rested on the edges of a slab foundation during framing operations. Violation observed on or about 3/11/14.
Recent events (2)
- — I (S) $600
- — Z (S) $1200
1926.451 E01
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $600.00 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access: a. East area - a ladder for access to the welded frame scaffold was not installed, in that, employees used endframes for access and were exposed to an 11 foot fall hazard. Violation observed on or about 3/11/14.
Recent events (2)
- — I (S) $600
- — Z (S) $1200
1926.451 G01
- Issued
- Penalty
- Initial $1020.00 · Current $510.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a. East wall - guardrails were missing on the end sections of the welded frame scaffold during framing operations and exposed employees to an 11 foot fall hazard. Violation observed on or about 3/11/14.
Recent events (2)
- — I (S) $510
- — Z (S) $1020
1926.451 G04 I
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms before being released for use by employees other than erection/dismantling crews: a. East wall - single cross bracing sections were used on open sides of platforms as both a mid and top rail during framing operations and exposed employees up to an 11 foot fall hazard. Violation observed on or about 3/11/14.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 238350)
JAMESTOWN, RI—2026-07-10
A K I CARPENTRY INC
BROOKLYN, NY—2026-07-08
PALACE RESIDENTIAL CORP.
BROOKLYN, NY—2026-07-07
PRO PROPERTY RENO INC.
KENTON, OH—2026-07-01
SUNLIGHT WINDOWS AND EXTERIORS, LLC
ROBBINSVILLE, NJ—2026-06-30
FAST WRAP WINDOWS & DOORS, INC.
More inspections in FL
MARIANNA, FL—2026-07-13
PRIMETIME MOBILE MASONRY LLC
MELBOURNE, FL—2026-07-13
OMNIPOTENT BRANDS, LLC
QUINCY, FL—2026-07-13
WALMART
INDIAN ROCKS BEACH, FL—2026-07-10
UNKNOWN CONTRACTOR
CLEARWATER, FL—2026-07-10
ROOFTECH ROOFING & WATERPROOFING INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339625501.