GREELEY, NE —
OSHA Inspection: SPALDING COOP ELEVATOR CO
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SPALDING COOP ELEVATOR CO in 109 S. RAILWAY AVE., GREELEY, NE 68842 (NAICS 424510). OSHA activity number 339627358.
Where did this inspection happen?
- Establishment
- SPALDING COOP ELEVATOR CO
- Site address
- 109 S. RAILWAY AVE.
- City
- GREELEY
- State
- NE
- ZIP
- 68842
- Mailing
- P.O. BOX B, SPALDING, NE 68665
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 424510
- Employees
- 100
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.215 A04
- Issued
- Penalty
- Initial $2380.00 · Current $1666.00 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: 109 S. Railway Ave., Greeley, NE 68842 (Maintenance Shop): The employer is failing to ensure that the opening between the work rest and abrasive wheel did not exceeded one-eighth inch on the 6 KT Industries bench grinder. The opening was three-eighths inch.
Recent events (2)
- — I (S) $1666
- — Z (S) $2380
1910.305 B01 II
- Issued
- Penalty
- Initial $2529.00 · Current $1770.00 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: 109 S. Railway Ave., Greeley, NE 68842 (Maintenance Shop): The employer is failing to ensure that an unused opening was closed for an electrical outlet box (Fuse box 4).
Recent events (2)
- — I (S) $1770.3
- — Z (S) $2529
1910.22 D01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed to the building: 109 S. Railway Ave., Greeley, NE 68842 (Maintenance Shop Over Bathroom): The employer is failing to ensure that the mezzanine on which air compressor and materials were stored had the load rating marked on it. Abatement certification is required for this violation. Abatement certification sheet is enclosed with the citation.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 424510)
POMEROY, WA—2026-07-01
WA317991893 - POMEROY GRAIN GROWERS INC
EDISON, NE—2026-06-30
AG VALLEY COOP
SCIO, OR—2026-06-10
317744473 - BEACON SEED LLC
HEALY, KS—2026-05-29
BARTLETT GRAIN CO
GOODLAND, KS—2026-05-28
THE SCOULAR COMPANY - GOODLAND
More inspections in NE
CRETE, NE—2026-07-15
SMITHFIELD FOODS
OMAHA, NE—2026-07-14
LACO ENTERPRISES, LLC
OMAHA, NE—2026-07-10
WINGSTOP
LINCOLN, NE—2026-07-01
SMITHFIELD PACKAGED MEATS CORP.
LINCOLN, NE—2026-06-30
PATRIOT PLUMBING, HEATING & AC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339627358.