Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: SPALDING COOP ELEVATOR CO

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SPALDING COOP ELEVATOR CO in 109 S. RAILWAY AVE., GREELEY, NE 68842 (NAICS 424510). OSHA activity number 339627358.

Watch Spalding Coop Elevator CO — free Get an email when a new federal OSHA severe-injury report for Spalding Coop Elevator CO is published. One employer, no account, unsubscribe in one click.
Site address
109 S. RAILWAY AVE.
City
GREELEY
State
NE
ZIP
68842
Mailing
P.O. BOX B, SPALDING, NE 68665
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424510
Employees
100
Ownership type
A

3 citations on file for this inspection.

1910.215 A04

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2380.00 · Current $1666.00 Reduced
29 CFR 1910.215(a)(4):  Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:                                                                                                                                 109 S. Railway Ave., Greeley, NE 68842 (Maintenance Shop): The employer is failing to ensure that the opening between the work rest and abrasive wheel did not exceeded one-eighth inch on the 6 KT Industries bench grinder. The opening was three-eighths inch.
Recent events (2)
  • — I (S) $1666
  • — Z (S) $2380

1910.305 B01 II

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2529.00 · Current $1770.00 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:    109 S. Railway Ave., Greeley, NE 68842 (Maintenance Shop): The employer is failing to ensure that an unused opening was closed for an electrical outlet box (Fuse box 4).
Recent events (2)
  • — I (S) $1770.3
  • — Z (S) $2529

1910.22 D01

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.22(d)(1):  On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed to the building:    109 S. Railway Ave., Greeley, NE 68842 (Maintenance Shop  Over Bathroom): The employer is failing to ensure that the mezzanine on which air compressor and materials were stored had the load rating marked on it.    Abatement certification is required for this violation.  Abatement certification sheet is enclosed with the citation.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339627358.