OSHA Inspection: JPG MANAGEMENT, LLC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of JPG MANAGEMENT, LLC. in MCDONALD'S RESTAURANT ROUTE 112, MAIN STREET, LINCOLN, NH 03251 (NAICS 722110). OSHA activity number 339629891.

Watch JPG Management, LLC. — free Get an email when a new federal OSHA severe-injury report for JPG Management, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
MCDONALD'S RESTAURANT ROUTE 112, MAIN STREET
City
LINCOLN
State
NH
ZIP
03251
Mailing
30 HENNIKER ST. UNIT 1., LINCOLN, NH 03251
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
722110
Employees
130
Ownership type
A

6 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $6300.00 · Current $6300.00
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that an employee was exposed to hazards including but not limited to cardiac arrest and serious interior/exterior electrical burns where emergency medical services were not immediately contacted after the employee received an electrical shock:  a. Site - On or about March 4, 2014, the employer failed to contact emergency medical services for an employee who had received an electrical shock. The employer delayed obtaining emergency medical care when it first contacted the business owner and then the injured employee's parents.  It was not until the employee's mother arrived at the restaurant that emergency medical care/911 were contacted.
Recent events (2)
  • — I (S) $6300
  • — Z (S) $6300

1910.101 B

Other-than-serious 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2700.00 · Current $0.00 Reduced
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6:    a. Site - On or about March 7, 2014, carbon dioxide cylinder tanks were not adequately stored or secured to prevent the tanks from being knocked over or damaged.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2700

1910.147 C01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $6300.00 · Current $6300.00
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    a. Site - On or about March 7, 2014, lockout/tagout training was not provided to employees who were exposed to electrical shock hazards.
Recent events (2)
  • — I (S) $6300
  • — Z (S) $6300

1910.303 B01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $6300.00 · Current $0.00 Reduced
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees, in that the employer did not ensure the safety of the equipment pursuant to the considerations in sections (i) through (viii) of 29 CR 1910.303(b)(1):    a. Site - On or about March 7, 2014, the electrical panel breakers used for servicing the center island equipment were not labeled or identified for their purpose.
Recent events (2)
  • — I (S) $0
  • — Z (S) $6300

1910.303 G02 I

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $6300.00 · Current $0.00 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):    a. Site - On or about March 3, 2014, an employee received serious electrical shock injures while cleaning around live parts not adequately guarded or protected.
Recent events (2)
  • — I (S) $0
  • — Z (S) $6300

1910.303 G01

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2700.00 · Current $1350.00 Reduced
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:    Instance a. Site - On or about March 7, 2014, the POS electrical panels was blocked and not made available for emergency or maintenance purposes.     Instance b. Site - On or about March 7, 2014, the electrical disconnect for the Multiplex Co. Inc. beverage dispensing machine was blocked and not made available for emergency or maintenance purposes.