HUMBLE, TX —
OSHA Inspection: ERASTO FLORES
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ERASTO FLORES in 20402 CANTON TRACE, HUMBLE, TX 77338 (NAICS 238130). OSHA activity number 339630469.
Where did this inspection happen?
- Establishment
- ERASTO FLORES
- Site address
- 20402 CANTON TRACE
- City
- HUMBLE
- State
- TX
- ZIP
- 77338
- Mailing
- 21188 CHERRY ST., NEW CANEY, TX 77357
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 10
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.95 A
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $2000.00
General-duty citation text
29 CFR 1926.95(a): Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, were not provided: The employer does not provide personal protective equipment. This violation was observed on or about March 13, 2014, at or near 20402 Canton Trace in Humble, TX, where employees were exposed to struck-by hazards when operating power tools and installing materials without eye, face, and head protection. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that protective equipment is provided for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, are provided.
Recent events (1)
- — Z (S) $2000
1926.451 C02
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $2000.00
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: The employer does not ensure scaffold poles bear on base plates, mud sills or other adequate firm foundation. This violation was observed on or about March 13, 2014, on the west side of a single family dwelling where employees were exposed to a 13 foot fall hazard when performing cornice work from pump jack scaffolding without the poles bearing on base plates, mud sills or other firm foundations. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that scaffold poles, legs, posts, frames, or uprights bear on base plates, mud sills or other adequate firm foundations.
Recent events (1)
- — Z (S) $2000
1926.451 C03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(c)(3): Supported scaffold poles, legs, posts, frames, and uprights shall be plumb and braced to prevent swaying and displacement. The employer does not ensure scaffold are plumb and braced to prevent swaying and displacement. This violation was observed on or about March 13, 2014, on the west side of a single family dwelling where employees were exposed to a 13 foot fall hazard when performing cornice work from pump jack scaffolding without the poles being plumb and braced. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that scaffold poles, legs, posts, frames, or uprights are plumb and braced to prevent swaying and displacement.
Recent events (1)
- — Z (S) $0
1926.451 G01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. The employer does not protect employees from falling when working 10 feet or more above a lower level. This violation was observed on or about March 13, 2014, on the west side of a single family dwelling where employees were exposed to a 13 foot fall hazard when performing cornice work from pump jack scaffolding without a fall protection system. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that each employee on a scaffold 10 feet or more above a lower level are protected from falling to a lower level.
Recent events (1)
- — Z (S) $2800
1926.452 J01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1926.452(j)(1): Pump jack brackets, braces, and accessories were not fabricated from metal plates and angles. Each pump jack bracket did not have two positive gripping mechanisms to prevent any failure or slippage. The employer does not ensure that brackets, braces, and accessories are fabricated from metal plates and angles. This violation was observed on or about March 13, 2014, on the west side of a single family dwelling where employees were exposed to a 13 foot fall hazard when performing cornice work from pump jack scaffolding with upper braces that were fabricated from plywood material. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that pump jack brackets, braces, and accessories are fabricated from metal plates and angles.
Recent events (1)
- — Z (S) $2800
1926.452 J02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. The employer does not ensure that poles are secured to the structure by rigid triangular bracing at the top, bottom, and other points as necessary. This violation was observed on or about March 13, 2014, on the west side of a single family dwelling where employees were exposed to a 13 foot fall hazard when performing cornice work from pump jack scaffolding without being properly secured at the top, bottom, and other points as necessary. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that poles are secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary.
Recent events (1)
- — Z (S) $0
More inspections in this industry (NAICS 238130)
FAIRHOPE, AL—2026-07-16
FRANCISCO ARES
WOODHAVEN, MI—2026-07-16
G.J. PERELLI CO., L.L.C.
PHILADELPHIA, PA—2026-07-16
URUS CONSTRUCTION CORPORATION
BERLIN, NJ—2026-07-16
URUS CONSTRUCTION CORPORATION
MERIDIAN, ID—2026-07-15
TRIPLE R CONSTRUCTION LLC
More inspections in TX
WICHITA FALLS, TX—2026-07-16
UNITED RENTALS, INC.
SAN MARCOS, TX—2026-07-16
CASA MECHANICAL SERVICES, LTD.
CLARKSVILLE, TX—2026-07-15
SEQUOIAS TREE EXPERT LLC
EL PASO, TX—2026-07-15
SURE STEEL
CORPUS CHRISTI, TX—2026-07-15
NORTH STAR ENERGY SOLUTIONS LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339630469.