2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: PHILO INSULATION & FIREPROOFING CO.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of PHILO INSULATION & FIREPROOFING CO. in 201 4TH STREET, SHOEMAKERSVILLE, PA 19555 (NAICS 238310). OSHA activity number 339631541.

Watch Philo Insulation & Fireproofing CO. — free Get an email when a new federal OSHA severe-injury report for Philo Insulation & Fireproofing CO. is published. One employer, no account, unsubscribe in one click.
Site address
201 4TH STREET
City
SHOEMAKERSVILLE
State
PA
ZIP
19555
Mailing
P.O. BOX 206, RIEGELSVILLE, PA 18077
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238310
Employees
5
Ownership type
A

2 citations on file for this inspection.

1910.134 C01

Serious Gravity 5 3 instances 1 exposed
Issued
Penalty
Initial $1360.00 · Current $1020.00 Reduced
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented where respirators were necessary to protect the health of the employee or whenever respirators were required by the employer: (Construction Reference 1926.103(a)):  (a) Philo Insulation & Fireproofing Co. - The employer did not develop and implement a written respiratory protection program for employees who are required to wear full-faced and 3M half-masked respirators while spraying diphenylmethane diisocyanate (MDI), on or about March 14, 2014.   (b) Philo Insulation & Fireproofing Co. - The employer did not provide employee training as required by paragraph 1910.134(c)(1)(vii) to employees who were required to wear full-face, 3M half-mask respirators while spraying diphenylmethane diisocyanate (MDI), on or about March 14, 2014.   (c) Philo Insulation & Fireproofing Co. - The employer did not establish or implement procedures to ensure that respirators were cleaned, disinfected and stored in a sanitary manner as required by paragraph 1910.134(c)(1)(v) after spraying diphenylmethane diisocyanate (MDI), on or about March 14, 2014.  (d) Philo Insulation & Fireproofing Co. -The employer did not establish or implement procedures to ensure that employees were medically evaluated as required by paragraph 1910.134(c)(1)(ii) before using respirators for spraying diphenylmethane diisocyanate (MDI), on or about March 14, 2014.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $1020
  • — Z (S) $1360

1910.134 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (Construction Reference 1926.103(a)):   (a) Philo Insulation $ Fireproofing, Co. - The employer did not provide a medical evaluation for employees who were required to wear a 3M half-mask respirator while spraying diphenylmethane diisocyanate (MDI) on the exterior of buildings, on or about March 14, 2014.      Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.