OSHA Inspection: CARPENTER POWDER PRODUCTS RI

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of CARPENTER POWDER PRODUCTS RI in 500 PARK EAST DRIVE, WOONSOCKET, RI 02895 (NAICS 332117). OSHA activity number 339632903.

Watch Carpenter Powder Products RI — free Get an email when a new federal OSHA severe-injury report for Carpenter Powder Products RI is published. One employer, no account, unsubscribe in one click.
Site address
500 PARK EAST DRIVE
City
WOONSOCKET
State
RI
ZIP
02895
Mailing
500 PARK EAST DRIVE, WOONSOCKET, RI 02895
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332117
Employees
20
Ownership type
A

2 citations on file for this inspection.

1910.157 D06

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $4590.00 · Current $4590.00
29 CFR 1910.157(d)(6): Portable fire extinguishers for Class D hazards were not required in those combustible metal-working areas where combustible metal powders, flakes, shavings, or similarly sized products are generated at least once every two weeks:  Packing Station: Where metal powders and metal powder blends were being packaged and stored, the employer did not require the presence and use of portable fire extinguishers for Class D hazards.  On 03/11/2014, a metal-based fire occurred at the Packing Station due to the discharge of static electricity.  The fire extinguisher available for employee use was labeled as a Class A/B/C, for ordinary combustibles, flammable liquids, and electrical equipment.
Recent events (2)
  • — I (S) $4590
  • — Z (S) $4590

1910.303 G01 I A

Other-than-serious 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $4590.00 · Current $0.00 Reduced
29 CFR 1910.303(g)(1)(i)(A): The depth of the working space in the direction of access to live parts may not be less than indicated in Table S-1.:    Packaging Room: Access to electrical equipment and manual shutoffs was less than that indicated in 1910.303, Table S-1.