OSHA Inspection: ENLINK MIDSTREAM SILVER CREEK

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ENLINK MIDSTREAM SILVER CREEK in 410 PEARSON RANCH ROAD, WEATHERFORD, TX 76087 (NAICS 424720). OSHA activity number 339637423.

Watch Enlink Midstream Silver Creek — free Get an email when a new federal OSHA severe-injury report for Enlink Midstream Silver Creek is published. One employer, no account, unsubscribe in one click.
Site address
410 PEARSON RANCH ROAD
City
WEATHERFORD
State
TX
ZIP
76087
Mailing
410 PEARSON RANCH ROAD, WEATHERFORD, TX 76087
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424720
Employees
7
Ownership type
A

2 citations on file for this inspection.

1910.119 D03 II

Deleted Serious Gravity 10 4 instances 5 exposed
Issued
Abate by
Penalty
Initial $7000.00 · Current $0.00 Reduced
29 CFR 1910.119(d)(3)(ii):  The employer did not document that the equipment in the process complied with recognized and generally accepted good engineering practices.     The employer does not ensure that it documents that equipment in the process complies with recognized and generally accepted good engineering practices.     The violation occurred in the Silver Creek Processing Facility on or about March 19, 2014 and at times prior thereto and after where the employer failed to ensure that an engineering evaluation of the inlet pressure drop that exceeded 3% of the relief device set pressure had been conducted in accordance with recognized and generally accepted good engineering practice such as, API STD 520 for relief device(s) such as but not limited to:        a.     PSV 501 (PCV 402B Failure, Inlet Pressure Drop at required rate > 7.9%)   b.     PSV 464 (External Fire, Inlet Pressure Drop at required rate > 10.0%)   c.     PSV 402 (External Fire, Inlet Pressure Drop at required rate > 3.5%)   d.     PSV 404 (External Fire, Inlet Pressure Drop at required rate > 7.1%)      Pursuant to 29 C.F.R. 1903.19, within (10) calendar days of the abatement date the employer must submit documentation showing that it is in compliance with the standard, including the description of the steps that it has taken to ensure that equipment complies with recognized and generally accepted good engineering practices.
Recent events (2)
  • — A (S) $0
  • — Z (S) $7000

1910.119 L01

Other-than-serious 68 instances 5 exposed
Issued
Abate by
Penalty
Initial $7000.00 · Current $4200.00 Reduced
29 CFR 1910.119(l)(1):  The employer did not establish and implement written procedures to manage changes to process chemicals, technology, equipment, and procedures; and, changes to facilities that affect a covered process.    The employer does not ensure that written procedures were established and implemented to manage changes to the process.      This violation occurred at the Enlink Midstream Silver Creek Facility on or about March 19, 2014 and at times prior thereto where the operating procedures did not include manufacturer safety factor 10% over the nameplate design capacity.    Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date the employer must submit documentation showing it is in compliance with the standard, including describing the steps it is taking to ensure that the written procedures were established and implemented to manage changes to the process.
Recent events (3)
  • — A (S) $7000
  • — I (O) $4200
  • — Z (S) $7000