Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SOUTH FALLSBURG DENTAL

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of SOUTH FALLSBURG DENTAL in 5203 MAIN STREET, SOUTH FALLSBURG, NY 12779 (NAICS 621210). OSHA activity number 339640328.

Watch South Fallsburg Dental — free Get an email when a new federal OSHA severe-injury report for South Fallsburg Dental is published. One employer, no account, unsubscribe in one click.
Site address
5203 MAIN STREET
City
SOUTH FALLSBURG
State
NY
ZIP
12779
Mailing
PO BOX 708, SOUTH FALLSBURG, NY 12779
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
621210
Employees
12
Ownership type
A

9 citations on file for this inspection.

1910.132 D01

Serious Gravity 5 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $2400.00 · Current $1800.00 Reduced
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE):   a)  Denture Laboratory - On and prior to March 19, 2014, employees were spraying Glutaraldehyde (corrosive) without wearing eye protection and while using Vintage Latex Powdered Examination Gloves (5 mil, deemed not adequate per glove manufacturer).  Glutaraldehyde can cause skin and eye burns.  b)  Denture Laboratory - On and prior to March 19, 2014, employees were grinding denture impressions without wearing eye protection.  Employees were exposed to flying particulate and dust.
Recent events (2)
  • — I (S) $1800
  • — Z (S) $2400

1910.151 C

Serious Gravity 5 1 instance 3 exposed
Issued
Penalty
Initial $2400.00 · Current $1800.00 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:   a)  Denture Laboratory - On and prior to March 19, 2014, for the laboratory employees using corrosive chemicals such as, but not limited to, Protectop 3.4% Glutaraldehyde.
Recent events (2)
  • — I (S) $1800
  • — Z (S) $2400

1910.157 E01

Serious Gravity 1 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $900.00 Reduced
29 CFR 1910.157(e)(1): The employer did not inspect, maintain or test portable fire extinguishers in the workplace:  a)  Denture Laboratory - On and prior to April 30, 2014, the 3 pound Kidde Regular Dry Chemical Extinguisher Model FA10G Number MU-026324 with manufacturer date of 1995 was not replaced within 12 years per the manufacturer recommendation.    b)  Denture Laboratory - On and prior to April 30, 2014, the 3 pound Kidde Regular Dry Chemical Extinguisher Model FA10G Number MU-026323 with manufacturer date of 1995 was not replaced within 12 years per the manufacturer recommendation.
Recent events (2)
  • — I (S) $900
  • — Z (S) $1200

1910.157 E02

Serious Gravity 1 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:   a)  Denture Laboratory - On and prior to April 30, 2014, the 3 pound Kidde Regular Dry Chemical Extinguisher Model FA10G Number MU-026324 with manufacturer date of 1995 was not inspected monthly.  The extinguisher was past the manufacturer service life.   b)  Denture Laboratory - On and prior to April 30, 2014, the 3 pound Kidde Regular Dry Chemical Extinguisher Model FA10G Number MU-026323 with manufacturer date of 1995  was not inspected monthly.  The extinguisher was past the manufacturer service life.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1030 C01 I

Serious Gravity 5 2 instances 6 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1500.00 Reduced
29 CFR 1910.1030(c)(1)(i): The employer having employee(s) with occupational exposure did not establish a written Exposure Control Plan designed to eliminate or minimize employee exposure:  a)  Denture Laboratory - On and prior to March 19, 2014, for the laboratory employees handling dental impressions with blood from patient's mouths.    b)  Dental Exam Rooms - On and prior to March 19, 2014, for the dentists and dental hygienists handling sharps while providing dental care to patients.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2000

1910.1200 E01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1500.00 Reduced

Hazardous substances 1361

29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii):   a)  South Fallsburg Dental - On and prior to March 19, 2014, for the laboratory employees using hazardous chemicals such as, but not limited to, Protectop 3.4% Glutaraldehyde (corrosive to eyes and skin, potential cause for occupational asthma, potential sensitizer), Ke-Solve solvent wax remover (flammable), and Vitacrilic Rapid Cure Monomer (flammable and potential sensitizer).
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2000

1910.1200 G08

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(g)(8): 29CFR1910.1200(g)(8): The employee did not maintain copies of the required safety data sheets for each hazardous chemical in the work place:   a)  South Fallsburg Dental - On and prior to March 19, 2014, for the laboratory employees using hazardous chemicals such as, but not limited to, Protectop 3.4% Glutaraldehyde (corrosive to eyes and skin, potential cause for occupational asthma, potential sensitizer), Ke-Solve solvent wax remover (flammable), and Vitacrilic Rapid Cure Monomer (flammable and potential sensitizer).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 H01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:   a)  South Fallsburg Dental - On and prior to March 19, 2014, for the laboratory employees using hazardous chemicals such as, but not limited to, Protectop 3.4% Glutaraldehyde (corrosive to eyes and skin, potential cause for occupational asthma, potential sensitizer), Ke-Solve solvent wax remover (flammable), and Vitacrilic Rapid Cure Monomer (flammable and potential sensitizer).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV B

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and/or cables were run through holes in walls, ceilings, or floors:  a) Denture Laboratory - On and prior to March 19, 2014, flexible cords were run through holes in the walls and ceiling.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339640328.