MONROE, NY —
OSHA Inspection: BERRIAN CONSTRUCTION, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of BERRIAN CONSTRUCTION, INC. in 556 ROUTE 17M, MONROE, NY 10950 (NAICS 238170). OSHA activity number 339647745.
Where did this inspection happen?
- Establishment
- BERRIAN CONSTRUCTION, INC.
- Site address
- 556 ROUTE 17M
- City
- MONROE
- State
- NY
- ZIP
- 10950
- Mailing
- P.O. BOX 29 9 BIRCHWOOD TERRACE, HYDE PARK, NY 12538
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 3
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.100 A
- Issued
- Penalty
- Initial $1200.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: (a) Front of the Building - on or about March 25, 2014 - protective hard hats were not worn by employees that were exposed to a head injury hazard.
Recent events (2)
- — I (S) $1000
- — Z (S) $1200
1926.453 B02 V
- Issued
- Penalty
- Initial $1600.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.453(b)(2)(v): A body belt was not worn and/or a lanyard was not attached to the boom or basket when working from an aerial lift:Note: (a) Front of Building - on or about March 25, 2014 - employees were not properly donning their personal fall arrest equipment while performing siding installations from the aerial boom man lift. Elevation of the lift basket to the ground was approximately 12 feet.
Recent events (2)
- — I (S) $1000
- — Z (S) $1600
1926.403 B02
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: (a) Front of the Building - on or about March 25, 2014 - the electric tools were plugged into a relocatable power tap. This equipment was not being used in accordance with its designed function.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 238170)
OXFORD, OH—2026-07-13
R&R SIDING LLC
WINSTON SALEM, NC—2026-07-10
161522 - MS SIDING LLC
SLINGER, WI—2026-07-10
DYLAN MATTHEW SHELLEY LLC
WINSTON SALEM, NC—2026-07-09
161514 - ALPHA OMEGA CONSTRUCTION GROUP, INC
ATLANTA, GA—2026-07-09
ESV CONSTRUCTION LLC
More inspections in NY
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
HEMPSTEAD, NY—2026-07-13
NYSDOCCS NASSAU AREA OFFICE
NIAGARA FALLS, NY—2026-07-10
NTVI FEDERAL INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339647745.