Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PRINTINGCENTERUSA.COM

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PRINTINGCENTERUSA.COM in 117 9TH ST. N., GREAT FALLS, MT 59401 (NAICS 323119). OSHA activity number 339650095.

Watch Printingcenterusa.Com — free Get an email when a new federal OSHA severe-injury report for Printingcenterusa.Com is published. One employer, no account, unsubscribe in one click.
Site address
117 9TH ST. N.
City
GREAT FALLS
State
MT
ZIP
59401
Mailing
117 9TH ST. N., GREAT FALLS, MT 59401
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
323119
Employees
20
Ownership type
A

7 citations on file for this inspection.

1910.36 D01

Deleted Serious Gravity 5 2 instances 20 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $0.00 Reduced
29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge:    (a) Copy room: On or about March 18, 2014, and at times prior,  employees were exposed to entrapment hazards from a double locking emergency exit door.                                                                             (b) Receiving area: On or about March 18, 2014, and at times prior,  employees were exposed to entrapment hazards from a double locking emergency exit door.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1600

1910.38 B

Serious Gravity 5 1 instance 20 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $800.00 Reduced
29 CFR 1910.38(b): An emergency action plan was not in writing, kept in the workplace, and available to employees for review:    (a) On or about March 18, 2014, and at times prior,  employees were exposed to entrapment hazards from the lack of an emergency action plan that outlined emergency evacuation procedures and duties.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1910.106 D04 I

Serious Gravity 10 1 instance 20 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2200.00 Reduced
29 CFR 1910.106(d)(4)(i): Opening(s) from inside flammable and combustible storage room(s) into other rooms or buildings were not provided with non combustible liquid tight raised seal or ramp at least 4 inches in height. Opening(s) from inside flammable and combustible storage room(s) were not provided with approved self-closing fire doors. The inside flammable and combustible storage room was not liquid tight where the walls joined the floor:    (a) Chemical storage room: On or about March 18, 2014, and at times prior, employees were exposed to fire and explosion hazards when flammable liquids, to include but not limited to ISOPROPANOL (Flash point 63 deg F), 7666 METERING ROLLER CLEANER (Flash point 10 deg F), WASH V-120 (106 deg F) were stored in a room that would not contain these flammable liquids in the event of a spill.
Recent events (2)
  • — I (S) $2200
  • — Z (S) $2800

1910.106 D04 IV

Serious Gravity 10 1 instance 20 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.106(d)(4)(iv): Every inside storage room was not provided with either a gravity or a mechanical exhaust ventilation system. Such system was not designed to provide for a complete change of air within the room at least six times per hour:    (a) Chemical storage room: On or about March 18, 2014, and at times prior, employees were exposed to fire and explosion hazards when flammable liquids, to include but not limited to ISOPROPANOL (Flash point 63 deg F), 7666 METERING ROLLER CLEANER (Flash point 10 deg F), and WASH V-120 (106 deg F) were stored without adequate ventilation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.106 D04 III

Serious Gravity 10 1 instance 20 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.106(d)(4)(iii): Electrical wiring and equipment located in inside storage room(s) used for Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), was not approved under subpart S of this part for Class I, Division 2 Hazardous Locations; for Category 3 flammable liquids with a flashpoint at or above 100 °F (37.8 °C) and Category 4 flammable liquids, was not approved for general use.    (a) Chemical storage room: On or about March 18, 2014, and at times prior, employees were exposed to fire and explosion hazards when flammable liquids, to include but not limited to ISOPROPANOL (Flash point 63 deg F), 7666 METERING ROLLER CLEANER (Flash point 10 deg F), and WASH V-120 (106 deg F) were stored in a non-intrinsically safe room.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.106 E06 II

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1400.00 Reduced
29 CFR 1910.106(e)(6)(ii): Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), were dispensed into containers without the nozzle and container being electrically interconnected:    (a) Chemical storage room: On or about March 18, 2014, and at times prior, employees were exposed to fire and explosion hazards while transferring flammable liquids, to include but not limited to ISOPROPANOL (Flash point 63 deg F), 7666 METERING ROLLER CLEANER (Flash point 10 deg F), and WASH V-120 (106 deg F) from bulk storage to smaller hand held secondary containers.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.151 C

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $800.00 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:    (a) Chemical storage room: On or about March 18, 2014, and at times prior, employees were exposed to moderate to severe eye irritation while transferring chemicals to include but not limited to ISOPROPANOL (2-Propanol, dimethyl carbinol), 7666 METERING ROLLER CLEANER (acetone, aliphatic hydrocarbon, heptane, isopropanol), WASH V-120 (petroleum naphtha, 1,2,4-trimethyl benzene, 1,8(9)-P-menthadiene, xylenes).
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339650095.